- The results display is not automatically cleared. In case of repairs and after repairs, check
the self-diagnosis screen and be sure to return the results display to "0".
- If the results display is not returned to "0" it will not be possible to judge a new malfunction
after completing repairs.
<Method of Clearing Results Display>
1. Power off (Set to the standby mode)
2.
DISPLAY
3. Channel
8
<Method of Ending Self-Diagnosis Screen>
- When ending the self-diagnosis screen completely, turn the power switch OFF on the
remote commander or the main unit.
5. Self-Diagnosis function operation
2
: Temp
3
: Lamp cover
4
: Fan
5
: Lamp Driver
6
: Low B error
7
: Audio
8
: D-OVP
9
: Panel error
10
: ATSC-OVP
LAMP
: Lamp
Channel
5
ENTER
When the temperature sensor (for Ambient) on the S1 board detects high
temperature or the temperature sensor (for Lamp) on the S2 board detects
high temperature or the temperature sensor (for Panel) on the C board detects
high temperature, the DE-micro (IC5) turns off the lamp.
The rib at the back of the lamp cover closes the SW on the T1 board. The lamp
closes the SW on the T2 board.
It is monitored by DE-micro (pin63 of IC5) and turned off the lamp when it is
opened.
Fan rotation is detected by ''FAN-PROT" and the DE-micro (pin92 of IC5) turns
off the lamp when it is ''high".
When the ''LAMP-PROT" (pin83 of IC5) is high, the lamp is not turned on.
If the ''LAMP-HV-DET" (pin94 of IC5) is low at the same time, it classified as
no high voltage of the lamp driver.
When no ''D5V (SW_5V)" is detected, pin 129 of TV-micro (IC7002) is low and
it turns off the main power. (for example, blowout of thermal fuse).
When DC voltage is detected at the speaker output, ''SP-PROT" (pin102 of IC5)
is low and it turns off the main power.
Be not in use.
When there is not ack from the temperature sensor on the S1, S2 and C board or
IIC line connector (CN2303: ASU board, CN7956: DSU board, CN6901: C board)
is not seated securely. it is monitored by DE-micro.
Be not in use.
When the ''LAMP-PROT" (pin83 of IC5) is high, the lamp is not turned on.
If the ''LAMP-HV-DET" (pin94 of IC5) is high at the same time, it classified
as no lamp or a dead lamp.