Power Supplies; Fans And Cooling - IBM System x3100 M5 Product Manual

Single-socket tower server
Hide thumbs Also See for System x3100 M5:
Table of Contents

Advertisement

Power supplies

Compact tower models either come with a single fixed 350 W ac power supply or a single fixed 80 PLUS
Bronze 300 W ac power supply. There are no additional power supply options.
Standard tower models offer one or two hot-swap 430 W ac power supplies, which are 80 PLUS Silver
certified. For models with only one power supply, the part number to order a second power supply is listed
in the following table. Two power supplies that are installed form a redundant pair.
Table 16. Hot-swap power supply option
Part number
00D3821

Fans and cooling

Both the compact tower design (with a single fixed power supply) and the standard tower design (with
hot-swap power supplies) come with one or two speed-controlled non-redundant fans, model dependent
(see Table 2). The second fan is required if two or more adapters are installed, and the fan is configured
by selecting the appropriate Thermal Solution Fan Kit, as listed in the following table.
If you want to operate the server in an environment up to 40°C (104°F), use the optional Operating
Temperature Enhancement Kit that is listed in the table. This kit contains an additional thermal sensor.
Table 17. Cooling options
Part number
For compact tower systems (with a fixed power supply)
46W9177
00Y8197
For standard tower systems (with hot-swap power supplies)
00Y8200
00FK940
IBM System x3100 M5 Product Guide
Feature
Description
code
A2Z0
430W Redundant Power Supply
Feature
Description
code
A3SF
System x3100 Thermal Solution Fan kit for 4U
Tower
A49B
System x3100 Operating Temperature
Enhancement Kit for 4U Tower
A49D
System x3100 Thermal Solution Fan kit for 5U
Tower
A49C
System x3100 Operating Temperature
Enhancement Kit for 5U Tower
Maximum
supported
1
Maximum
supported
1
1
1
1
20

Advertisement

Table of Contents
loading

Table of Contents