Maintenance / Inspection Intervals; Service Tips; Drive Belts; Fuel Tank Drain - Foretravel U270 Owner's Manual

Foretravel motorhome owners manual
Table of Contents

Advertisement

Foretravel Owners Manual
MAINTENANCE / INSPECTION
SEE SEPARATE FORETRAVEL & GENERATOR

MAINTENANCE SCHEDULE

S
T
ERVICE
IPS

1. DRIVE BELTS

Belts should be checked for frayed areas, cracks and general wear. Always
replace belts in a set, even though only one belt is defective. Tension belts so
that 25 lbs. (firm thumb pressure) midway between pulleys will deflect the
belts 1/2 to 3/4 inch for the first check. Insure that all adjustment/mounting
bolts are tight. Recheck belt tension after 1/2 hour or 15 miles of operation.
Maintain later adjustment at 7/8 inch deflection.
WARNING
Safety goggles should be worn to protect eyes when performing the
following checks.

2. FUEL TANK DRAIN

Drain fuel tank by removing drain plug and drain until all water and sedi-
ment is discharged. Replace drain plug.

3. AIR CLEANER

Check air intake system to be sure all ducting is air tight.
a. Check the air transfer duct between the air cleaner and the engine to be sure
all clamps are tight, all flange joints tight, and there are no cracks in the
ducting.
b. Air cleaner mounting bolts and clamps must be tight to hold the air cleaner
securely.

4. FUEL FILTER

Service in accordance with the Foretravel Maintenance Schedule book
and instructions in the Engine Manufacturers Operator's Manual. See Appen-
dix C also.

5. TEST ANTI-FREEZE SOLUTION

Use a hydrometer in checking anti-freeze solution. Follow instructions
Rev. 06-02
Section 14 - Maintenance / Inspection Intervals
INTERVALS
Page 14-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

U295U320U320 4200Gv320U320-gv320

Table of Contents