S e r v i c e I n f o r m a t i o n
4.
Plug the five DC power cables into their respective connectors on
the power distribution board at the top of the electronics chamber.
These connectors are keyed and cannot be plugged incorrectly. Do
not use force; you may be trying to plug a cable into the wrong
connector.
5.
Replace all CPU, memory and other expansion cards and connect
their respective cables appropriately.
6.
Replace the support straps for the CPU/memory slots.
7.
Replace the SMIC card and plug its cable into the power
distribution board at the top of the electronics chamber. Fasten the
plug using the latches as shown in the following diagram:
Figure 4-44 SMIC Connector Ejector Latches
1.
Ejector Latches
8.
Replace the six screws which secure the connector subplate, on the
back panel, to the server chassis.
9.
Hook the left edge of the protective metal plate in place and secure
the plate to the server chassis using the screws along the top and
right edges.
10. Reconnect all cables and leads to the back panel port connectors.
Note
You should always fit all protective metal plates. These plates, in addition to
providing protection for delicate components, contribute to an effective flow of cool
air through the machine.