Memory Test - Toshiba Portege M200 Maintenance Manual

Hide thumbs Also See for Portege M200:
Table of Contents

Advertisement

3 Tests and Diagnostics
3.6

Memory Test

To execute the Memory Test, select 2-MOMORY TEST from the DIAGNOSTIC TEST menu,
press Enter and follow the directions on the screen. The Memory test consists of five subtests. Set
the highlight bar to the subtest you want to execute and press Enter.
Subtest 01
Conventional Memory
This subtest writes test data to conventional memory (0 to 640 KB), and reads and
compares the result with the original data. The test address is displayed per 4 KB.
Subtest 02
Protected Mode
NOTE: The CONFIG.SYS file must be configured without extended memory manager
programs such as EMM386.EXE, EMM386.SYS or QEMM386.SYS. Also, the HIMEM.SYS
must be deleted from the CONFIG.SYS file.
This subtest writes constant data and address data (from 1MB to maximum MB),
and reads the new data and compares the result with the original data.
Subtest 04
Cache Memory
To test the cache memory, a pass-through write-read comparison of '5A' data is
run repeatedly to the test area (from '7000':'Program' size to '7000':'7EEE' (32
KB)) to check the hit-miss ratio (on/off status) for CPU cache memory.
Number of misses < Number of hits → OK
Number of misses ≥ Number of hits → NG
3-16
Portege M200 Maintenance Manual (960-457)
3.6 Memory Test