Image Ship - Imgshp; Imgshp Modifiers - Honeywell Xenon 1900 User Manual

Area-imaging scanner
Hide thumbs Also See for Xenon 1900:
Table of Contents

Advertisement

W - Target White Value
Sets the target for the median grayscale value in the captured image. For capturing close-up images of high contrast doc-
uments, a lower setting, such as 75, is recommended. Higher settings result in longer exposure times and brighter images,
but if the setting is too high, the image may be overexposed. Target White Value is only available when using Photo Style
(1P). (Default = 125)
n W Range: 0 - 255
Example of White
Value at 75W:
D - Delta for Acceptance
This sets the allowable range for the white value setting (see
Photo Style (1P). (Default = 25)
n D Range: 0 - 255
U - Update Tries
This sets the maximum number of frames the scanner should take to reach the
only available when using Photo Style (1P). (Default = 6)
n U Range: 0 - 10
% - Target Set Point Percentage
Sets the target point for the light and dark values in the captured image. A setting of 75% means 75% of the pixels are at or
below the target white value, and 25% of the pixels are above the target white value. Altering this setting from the default is
not recommended under normal circumstances. To alter grayscale values,
(Default = 50)
n% Range: 1 - 99
Step 2 - Ship a Picture Using IMGSHP

Image Ship - IMGSHP

An image is taken whenever the button is pressed, or when the Image Snap (IMGSNP) command is processed. The last image
is always stored in memory. You can "ship" the image by using the IMGSHP command.
The image ship commands have many different modifiers that can be used to change the look of the image output. Modifiers
affect the image that is transmitted, but do not affect the image in memory. Any number of modifiers may be appended to the
IMGSHP command. For example, you can use the following command to snap and ship a bitmap image with gamma correction
and document image filtering: IMGSNP;IMGSHP8F75K26U

IMGSHP Modifiers

A - Infinity Filter
Example of Target
Example of Target
Set Point
Set Point
Percentage at 97%:
Percentage at 50%:
Example of White
Value at 125W:
W - Target White
W - Target White Value
Example of Target
Set Point
Percentage at 40%:
Example of White
Value at 200W:
Value). Delta is only available when using
D - Delta for
Acceptance. Update Tries is
should be used.
8 - 3

Advertisement

Table of Contents
loading

Table of Contents