Suzuki GSX-R750 Service Manual page 299

Hide thumbs Also See for GSX-R750:
Table of Contents

Advertisement

• To set the EXCV to fully close position, apply 12 V to A and
B terminals.
Battery + terminal–– A (Pink lead wire) terminal
Battery - terminal–– B (Gray lead wire) terminal
To prevent the motor damage, stop applying 12 V as
soon as the EXCV reaches fully close position.
• Turn the ignition switch ON.
• Measure the position sensor output voltage at fully close posi-
tion.
 Position sensor output voltage
EXCV is fully close: 0.5
 09900-25008: Multi circuit tester set
09900-25009: Needle pointed probe set
 Tester knob indication: Voltage ()
If the measured voltage is less than specification, adjust the
No.1 cable adjuster as follows:
• Set the EXCVA to adjustment position. (6-4)
Adjusting the No.1 cable with the EXCV fully closed
can damage the EXCVA. Be sure to adjust the No.1
cable with the EXCV set in adjustment position.
• Turn out the No.1 cable adjuster 3.
• Repeat the above procedure until the output voltage becomes
specified value.
 Position sensor output voltage
EXCV is fully close: 0.5
• To next step.
NOTE:
If C46 code is indicated after adjusting the voltage, increase the
voltage to 0.9 V.
4th step:
To set the EXCV to fully open position, apply 12 V to A and B
terminals.
Battery + terminal–– B (Gray lead wire) terminal
Battery - terminal–– A (Pink lead wire) terminal
To prevent the motor damage, stop applying 12 V as
soon as the EXCV reaches fully open position.
output voltage
(+ Yellow – - B/Br)
output voltage
V
1.3 (V)
1.3 (V)
EXHAUST SYSTEM
6-9
12 V
12 V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gsx-r600 2006Gsx-r600 20072007 gsxr 6002006 gsxr 600

Table of Contents