C31" (P0705) Gp Switch Circuit Malfunction - Suzuki GSX-R750 Service Manual

Hide thumbs Also See for GSX-R750:
Table of Contents

Advertisement

"C31" (P0705) GP SWITCH CIRCUIT MALFUNCTION

DETECTED CONDITION
No Gear Position switch voltage
Switch voltage is not within the following range.
Switch voltage > 0.6 V
ECM
GP
E1
INSPECTION
Step 1
1) Turn the ignition switch OFF.
2) Lift and support the fuel tank. (5-3)
3) Check the GP switch coupler for loose or poor contacts.
If OK, then measure the GP switch voltage.
4) Support the motorcycle with a jack.
5) Fold the side-stand to up position.
6) Make sure the engine stop switch is in the "RUN" position.
7) Insert the needle pointed probe to the lead wire coupler.
8) Turn the ignition switch ON.
9) Measure the voltage at the wire side coupler between P wire
and B/W wire, when shifting the gearshift lever from 1st to
Top.
 GP switch voltage: 0.6 V and more
 09900-25008: Multi-circuit tester set
09900-25009: Needle pointed probe set
 Tester knob indication: Voltage ()
To engine stop switch
GP switch
BI
P
P
6
B/W
5
B/W
4
(+ P – - B/W)
POSSIBLE CAUSE
• Gear Position switch circuit open or short
• Gear Position switch malfunction
• ECM malfunction
Side-stand relay
N
1
Neutral indicator
light
2
3
Side-stand switch
1
1
FI SYSTEM DIAGNOSIS
4-75
Ignition
switch
V