WINDING MECHANISM

When the camera shows the conditions described below, it may be assumed that the Winding Mechanism has
become defective and so the following adjustments should be made:
When the shutter is not charged even after the Trigger Lever is wound, the following adjustments should be made:
Loosen Screw B1190. float Winding Device C9266-11 and set the Shutter w i t h a pair of tweezers.
Then adjust the amount of charge by turning the Eccentric Screw of C9266-11.
When the Trigger Lever dnes not move, the following checks and adjustments should be made:
1. Check to see whether the Screw for the Winding Device is loose.
2. Check to see whether Snring C4049 is out of place.
3. If Cone C4090 is caught between Lever C9267 and Lever C4051-03. loosen Screw S1777 and adiust C4090
by turning it to the right.
4. If Lever C4051-03 does not disengage
because Cone C4090 does not go down enough, Screw S1777 should be loosened and adjustments made by
turning C4090 to the left.
When the Trigger Lever runs idle or when it winds many times before the shutter button is pressed down,
the following checks and adiustments should be made:
1. Check to see whether Spring C4042 is out of place.
2
If the spindle of Lever C4044 is bent, rentace Base Plate C9262-09.
If so, reattacii.
itself f r o m Lever C4044 when the shutter N i t r o n is pressed down
If so. reattach.
8
See Repair Manual p.5.
See Repair Manual p.5.
See Repair Manual pp 2&5