Electrical Connection; Connecting The Mains Supply Cable; Replacing The Mains Supply Cable - IAG ICS6SE3 Manual

600mm electric cooktop with solid elements
Table of Contents

Advertisement

Electrical connection 
 
This appliance must be installed by a qualified person. 
 
Before connecting the appliance, make sure that the supply voltage marked on the 
rating plate corresponds with your mains supply voltage. 
 
WARNING: THIS APPLIANCE MUST BE EARTHED. 
 This appliance must be wired into a 30 A double pole switched fused spur outlet, having 3 mm 
contact separation and placed in an easily accessible position adjacent to the appliance. It should 
not be located above the appliance and no more than 1.25m away from it. 
 The spur outlet must still be accessible even when your oven is located in its operating position. 
 Cable type: H05 RRF 3 core x 2.5 mm² 
 
Connecting the mains supply cable 
 The mains terminal block is located on the underside of the hob and the terminals are accessible 
by removing the terminal block cover by removing the cover screw. 
 The cable connections must be in accordance with the diagram located on the bottom of the hob. 
 The brass links must be positioned as marked in the appropriate diagram and once established ALL 
terminal screws must be tightened down firmly. 
 If when the hob is first switched on, only two of the zones work, you should recheck that the 
terminal screws are all fully tightened between the links.   
 IMPORTANT: The appliance must NOT be connected to the mains supply by means of a 13A plug 
and socket. 
 The cable can be looped if necessary, but make sure that is not kinked or trapped when the hob is 
in position. Care must be taken to avoid the cable being in contact with hot parts of the appliance. 
 
Replacing the mains supply cable 
If the mains supply cable is damaged, then it must be replaced by an appropriate replacement which 
can be obtained from the Seller. The mains supply cable should be replaced in accordance with the 
following instructions: 
 Switch the appliance off at the control switch. 
 Open the terminal block on the underside of the hob. 
 Unscrew the terminal screws fixing the cable. 
 Replace the cable with one of the same length and in accordance with the specification given 
above. 
 The "green‐yellow" earth wire must be connected to the terminal marked . It must be about 10 
mm longer than the live and neutral wires. 
The "blue" neutral wire must be connected to the terminal marked with letter (N) ‐ the live wire 
must be connected to the terminal marked with letter (L).
ACS6SE2 and ICS6SE3 60cm Cooktop Installation and Operation Manual
 
 
- 11 -
 
 

Advertisement

Table of Contents
loading