BATTERY AND FUSE REPLACEMENT
WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before
removing the battery cover.
1. Turn power off and disconnect the test leads from the meter.
2. Open the rear battery/fuse compartment by removing the Phillips head screw on the lower rear of
the meter. .
3. Pull down on the cover to release the latch and then lift it off.
4. Remove the old battery or fuse and install a new one of the correct rating.
5. Place the battery/fuse cover back in place. Secure with the screw.
WARNING: To avoid electric shock, do not operate the meter until the battery cover is in place and
fastened securely.
NOTE: If the meter does not work properly, check the fuses and replace the battery to make sure that
they are still good and that they are properly inserted.