Introduction The information provided in this Technical Configuration Guide will assist you in configuring the FFx-RAID controller installed in a PRIMERGY S60 storage subsystem. For other manuals that are needed during configuration see entries in the chapter “Related Publications” on page 55.
(see section “DIP Switches Settings for Different Connections” on page 6). Ê If needed, refer to the Operating Manual for the PRIMERGY S60 [6] and install the FFx-RAID controller in the storage subsystem. If this is a single controller installation, the FFx-RAID controller must be installed in slot 0 (as DAC 0, see figure 1 on page 4).
Page 10
G B I C B a y V T 1 0 0 - D E B U G Figure 1: PRIMERGY S60 Storage Subsystem: Rear Ê Connect the storage subsystem to a power source. Ê Power ON the storage subsystem.
Page 11
It is embedded in the firmware that controls the operation of the FFx-RAID controller(s) delivered with the PRIMERGY S60 storage subsystem. It can be accessed by connecting the delivered serial RS-232 interface cable...
Installing the Hardware Configuring the FFx-RAID Ctlr. 2.1.1 DIP Switches Settings for Different Connections Two DIP switch fields are available on the host adapter of the FFx-RAID controller, J1-J4 and K1-K4. The DIP switches J3, J4 and K4 are important for the connection types.
Page 13
Configuring the FFx-RAID Ctlr. Installing the Hardware Direct Connection to a HBA or to a Cascaded HUB For this connection the default setting are used (see also figure 2 on page 6): Switch Position Connection to a Switch via the HSSDC Connector (GBIC disabled) Switch Position Connection to a Switch via the GBIC Connector (HSSDC disabled)
FFx-RAID Controller Parameter Settings Configuring the FFx-RAID Ctlr. 2.2.1 Simplex Configuration ATTENTION! Not all parameters can be accessed through the SAM software. Ê Display the SAM Controller Information window (figure 3) by clicking Admin- istration/Controller Information on the menu bar or the Controller Information icon.
Page 17
Configuring the FFx-RAID Ctlr. FFx-RAID Controller Parameter Settings For more information see “Setting and Modifying Controller Options” in the SAM documentation. Figure 4: SAM Basic Controller Options Dialog Box (simplex) Ê Open the Basic dialog box and set the parameters as shown in figure 4. Figure 5: SAM Advanced Controller Options Dialog Box (simplex) P15355-P111-Z139-5-7619...
Page 18
FFx-RAID Controller Parameter Settings Configuring the FFx-RAID Ctlr. Ê Open the Advanced dialog box and set the parameters as shown in figure 5. Figure 6: SAM Expert Controller Options Dialog Box (simplex) Ê Open the Expert dialog box and set the parameters as shown in figure 6. Figure 7: SAM Fibre Controller Options Dialog Box (simplex) P15355-P111-Z139-5-7619...
Configuring the FFx-RAID Ctlr. FFx-RAID Controller Parameter Settings Ê Open the Fibre dialog box and set the parameters as shown in figure 7. 2.2.2 Dual Active Configuration Use the same procedure for setting the controller parameter in a dual active configuration as shown in the figures below.
9 on page 51) must be set to 1. The LUN per Target (parameter 1.5.4 in table 6 on page 50) must be set to the number of LUNs configured in the PRIMERGY S60 (maximum 32) when booting from a FFx-RAID controller.
Configurations The FFx-RAID controllers use RAID technology to provide protection against drive failures. The FFx-RAID controllers also support configurations that employ multiple hosts and redundant controllers for improved fault-tolerance and high- performance data through-put. This chapter provides examples of non- clustering and cluster server single and dual-active controller configurations in host cabling topologies.
● to 10 km), requires HUB or switch with one MMF GBIC and one SMF GBIC, MMF HBA for the server and SMF GBIC plugged into the PRIMERGY S60 ● SMF connections between HUB or switch and PRIMERGY S60 are also...
Page 25
Configurations Non Cluster Configurations Figure 15: Direct Attached Storage Subsystem P15355-P111-Z139-5-7619...
● host connector with MMF (up to 500 m), MMF HBA and GBIC with MMF interface plugged into the PRIMERGY S60 necessary ● copper cable (3 m) with HSSDC connector for FFx-RAID controller module to module connection optional use of MMF cables (up to 500 m) with MMF HBA and one MMF ●...
Page 27
Configurations Non Cluster Configurations Figure 16: Direct Attached Storage Subsystem with Controller Fail Over P15355-P111-Z139-5-7619...
(up to 10 m) are ● preferred, no GBIC needed ● optional use of MMF cables (up to 500 m) with MMF HBA and two MMF GBIC plugged into the PRIMERGY S60 Configuration hints ● Fibre-Topology: Multi Port ●...
(up to 10 m) are ● preferred, one copper GBIC needed ● optional use of MMF cables (up to 500 m) with MMF HBAs, one MMF GBIC and MIA plugged into the PRIMERGY S60 Configuration hints ● Fibre-Topology: - ●...
Page 31
Configurations Path Redundancy Configurations Figure 18: Path Redundancy with Single FFx-RAID Controller P15355-P111-Z139-5-7619...
MMF cables (up to 500 m) between server with MMF HBA ● and PRIMERGY S60, two MMF GBIC necessary instead of copper GBICs plugged into the PRIMERGY S60. Copper cables for PRIMERGY S60 to PRIMERGY S60 connection are still used DuplexDataManager (MultiPath and DuplexWrite) necessary ●...
(up to 10 m) are preferred, one copper GBIC needed ● optional use of MMF cables (up to 500 m) with MMF HBAs and one MMF GBIC plugged into the PRIMERGY S60. FFx configuration hints ● Fibre-Topology: - ●...
Linux Cluster with Reliant Cluster in preparation (no SAM server/driver ● available) for rack internal connections low cost copper cables (up to 10 m) are ● preferred, one copper GBIC at PRIMERGY S60 is needed FFx configuration hints Fibre-Topology: Multi-TID ● Loop IDs (see figure 21 on page 30) ●...
Configurations Cluster Configurations 3.3.3 Entry Cluster with Dual RAID Controller Description no path redundancy ● Microsoft Cluster released and certified ● ● Linux Cluster with Reliant Cluster in preparation (no SAM server/driver available) for rack internal connections low cost copper cables (up to 10 m) are ●...
Cluster Configurations Configurations 3.3.4 Cluster with DuplexWrite Description Microsoft Cluster released and certified ● for rack internal connections low cost copper cables (up to 10 m) are ● preferred, two copper GBICs needed DuplexDataManager (DuplexWrite) needed ● FFx configuration hints Fibre-Topology: - ●...
Cluster Configurations Configurations 3.3.5 Cluster with MultiPath Description Microsoft Cluster released and certified ● for rack internal connections low cost copper cables (up to 10 m) are ● preferred, two copper GBICs needed DuplexDataManager (MultiPath) necessary ● FFx configuration hints Fibre-Topology: Multi-Port ●...
LUN Mapping: affinity to all ports, enable all hosts or configure as needed ● optional use MMF cables (up to 500 m) with MMF HBA and MMF GBIC ● plugged into the PRIMERGY S60 DuplexDataManager (MultiPath and DuplexWrite) necessary ● P15355-P111-Z139-5-7619...
Page 43
Configurations Cluster Configurations Figure 25: Cluster with MultiPath and DuplexWrite P15355-P111-Z139-5-7619...
LUN Mapping: affinity to all ports, enable all hosts or configure as needed ● optional use MMF cables (up to 500 m) with MMF HBA and MMF GBIC ● plugged into the PRIMERGY S60 ● DuplexDataManager (MultiPath and DuplexWrite) necessary ●...
Page 45
Configurations Cluster Configurations Figure 26: Cluster with MultiPath and DuplexWrite in a Switch Configuration P15355-P111-Z139-5-7619...
SAN Mapping Configurations Configurations SAN Mapping Configurations 3.4.1 SAN Mapping without External HUB/Switch Configuration hints ● Fibre-Topology: - ● Loop IDs (see figure 27 on page 40) ● LUN affinity as needed Figure 27: SAN Mapping without External HUB/Switch P15355-P111-Z139-5-7619...
Configurations SAN Mapping Configurations 3.4.2 Standard SAN Mapping in Switch Configuration Configuration hints Fibre-Topology: - ● LUN Mapping: affinity to C0P0, host-to-LUN-mapping ● ● up to four PRIMERGY servers are released in configurations with switches MMF is the preferred connection medium ●...
Page 48
SAN Mapping Configurations Configurations Figure 28: Standard SAN Mapping in Switch Configuration P15355-P111-Z139-5-7619...
SAN Mapping with Controller Fail Over in Switch Configuration PRIMERGY S60 configurations with both FFx-RAID controller in the same loop attached to a fibre channel switch can not be supported. Due to a technical modification of the mini HUB this configuration must be withdrawn.
Page 50
SAN Mapping Configurations Configurations Figure 29: SAN Mapping with MultiPath in Switch Configuration P15355-P111-Z139-5-7619...
Configurations SAN Mapping Configurations 3.4.5 SAN Mapping with MultiPath and DuplexWrite in Switch Configuration Configuration hints Fibre-Topology: Multi Port ● ● LUN Mapping: affinity to all ports, host-to-LUN-mapping up to four PRIMERGY servers are released ● ● in configurations with switches MMF is the preferred connection medium DuplexDataManager (MultiPath and DuplexWrite) necessary ●...
Page 52
SAN Mapping Configurations Configurations Figure 30: SAN Mapping with MultiPath and DuplexWrite in Switch Configuration P15355-P111-Z139-5-7619...
QLA2200 Fibre Channel HBA The settings described in this chapter are valid for QLA FW 1.61 only. Fujitsu Siemens Computers recommends configuring the Qlogic BIOS settings with the FSC-approved NVRAM settings file. This contains all the BIOS settings for the QLA2200 HBA that have been tested and approved for connection to storage subsystems (like PRIMERGY S60) in RAID configurations.
Page 54
Configuration Settings for QLA2200 Appendix 3. Select Configuration Settings (see table 1 on page 49) from the Fast!UTIL Options menu and press Enter Ú. 4. Select Extended Firmware Settings (submenu no. 1.6; see table 2 on page 49) from the Configuration Settings menu and press Enter Ú. 5.
Appendix Configuration Settings for QLA2200 4.1.1 Fast!UTIL - Menus (QLA Bios 1.61, see FSC-Mailbox) Menu No. Fast!UTIL Options Configuration Settings Scan Fibre Devices Fibre Disk Utility Select Host Adapter Exit Fast!Util Table 1: Fast!UTIL Options menu Submenu Configuration Settings No. 1 Host Adapter Settings Selectable Boot Settings Restore Default Settings...
Page 56
Configuration Settings for QLA2200 Appendix Submenu Selectable Boot Settings Options Default No. 1.2 1.2.1 Selectable Boot Device disabled 1.2.2 Current Boot Node Name (see table 5 0000000000000000 below) 1.2.3 Current Boot LUN Number Table 4: Selectable Boot Settings submenu Submenu Host Adapter Settings No.
Page 57
Appendix Configuration Settings for QLA2200 Submenu Advanced Adapter Settings Options Default No. 1.5 1.5.13 IOCB Allocations 0-512 1.5.14 Extended Error Login disabled Table 6: Advanced Adapter Settings submenu Submenu LUN per Target Option No. 1.5.4 Value 1.5.4.1 QLA2200 is running on a WINNT4.0/WIN2000 system platform 1.5.4.2 QLA2200 is running on a system platform other than...
Page 58
Configuration Settings for QLA2200 Appendix Submenu Extended Firmware Settings Options Default No. 1.6 1.6.3 Connection Options (see also section “Qlogic Loop Only Configuration Hints” on Point to Point Only page 16) Loop Preferred, otherwise Point to Point Point to Point, otherwise Loop 1.6.4 NonParticipating Hard ID...
Abbreviations Disk Array Controller DuplexDataManager Fiber Channel GBIC Gigabit Interface Converter Host Bus Adapter HSSDC High Speed Serial Direct Connect Logical Unit Number Multi Mode Fibre RAID Redundant Arrays of Independent Disks SAN Array Manager SCSI Small Computer System Interface Single Mode Fibre P15355-P111-Z139-5-7619...
Installation Guide and User Manual Global Array Manager™ Server Software Installation Guide and User Manual SANArray Manager™ Client Software Installation Guide and User Manual Embedded Configuration Utility User’s Guide PRIMERGY S60 Server Subsystem Operating Manual Hardware Installation Guide for the QLA2200/2200F/2202F P15355-P111-Z139-5-7619...
Page 65
Fujitsu Siemens Computers GmbH Comments User Documentation 81730 M ünchen Suggestions Germany Corrections Fax: (++49) 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on PRIMERGY S60 Storage Subsystem P15355-P111-Z139-5-7619...
Page 67
Fujitsu Siemens Computers GmbH Comments User Documentation 81730 M ünchen Suggestions Germany Corrections Fax: (++49) 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on PRIMERGY S60 Storage Subsystem P15355-P111-Z139-5-7619...
Page 69
Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.