Primergy
PRIMERGY S60
Storage Subsystem
Technical Configuration Guide
Xenia Fierley
Fujitsu Siemens Computers GmbH cognitas PS
81730 München
e-mail: email:manuals@fujitsu-siemens.com
Tel.: (089) 61001-157
Fax: (++49) 700 / 372 00000
P15355-P111-Z139-5-7619
Sprachen: En
Edition August 2002

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu Siemens Computers Primergy S60

  • Page 1 Primergy PRIMERGY S60 Storage Subsystem Technical Configuration Guide Xenia Fierley Fujitsu Siemens Computers GmbH cognitas PS 81730 München e-mail: email:manuals@fujitsu-siemens.com Tel.: (089) 61001-157 Fax: (++49) 700 / 372 00000 P15355-P111-Z139-5-7619 Sprachen: En Edition August 2002...
  • Page 2: Copyright And Trademarks

    Gesellschaft für Technik-Dokumentation mbH www.cognitas.de Copyright and Trademarks Copyright © 2002 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
  • Page 3 Introduction Configuring the FFx-RAID Ctrl. Configurations Appendix Related Publications and Index...
  • Page 5: Table Of Contents

    Contents Introduction ......1 Target Group ......1 Notation Conventions .
  • Page 6 Contents Appendix ......47 Recommended Configuration Settings for QLA2200 Fibre Channel HBA ....47 4.1.1 Fast!UTIL - Menus .
  • Page 7: Introduction

    Introduction The information provided in this Technical Configuration Guide will assist you in configuring the FFx-RAID controller installed in a PRIMERGY S60 storage subsystem. For other manuals that are needed during configuration see entries in the chapter “Related Publications” on page 55.
  • Page 9: Configuring The Ffx-Raid Ctlr

    (see section “DIP Switches Settings for Different Connections” on page 6). Ê If needed, refer to the Operating Manual for the PRIMERGY S60 [6] and install the FFx-RAID controller in the storage subsystem. If this is a single controller installation, the FFx-RAID controller must be installed in slot 0 (as DAC 0, see figure 1 on page 4).
  • Page 10 G B I C B a y V T 1 0 0 - D E B U G Figure 1: PRIMERGY S60 Storage Subsystem: Rear Ê Connect the storage subsystem to a power source. Ê Power ON the storage subsystem.
  • Page 11 It is embedded in the firmware that controls the operation of the FFx-RAID controller(s) delivered with the PRIMERGY S60 storage subsystem. It can be accessed by connecting the delivered serial RS-232 interface cable...
  • Page 12: Dip Switches Settings For Different Connections

    Installing the Hardware Configuring the FFx-RAID Ctlr. 2.1.1 DIP Switches Settings for Different Connections Two DIP switch fields are available on the host adapter of the FFx-RAID controller, J1-J4 and K1-K4. The DIP switches J3, J4 and K4 are important for the connection types.
  • Page 13 Configuring the FFx-RAID Ctlr. Installing the Hardware Direct Connection to a HBA or to a Cascaded HUB For this connection the default setting are used (see also figure 2 on page 6): Switch Position Connection to a Switch via the HSSDC Connector (GBIC disabled) Switch Position Connection to a Switch via the GBIC Connector (HSSDC disabled)
  • Page 14: Ffx-Raid Controller Parameter Settings

    FFx-RAID Controller Parameter Settings Configuring the FFx-RAID Ctlr. FFx-RAID Controller Parameter Settings Read Ahead : Enabled Super Read Ahead : Disabled Enable Background Initialization : Enabled Rebuild Rate : 50 Spin Up : Automatic / 2 / 6 / 0 Devices per Spin Initial Delay Sequential Delay...
  • Page 15 Configuring the FFx-RAID Ctlr. FFx-RAID Controller Parameter Settings SLP/VT100 : VT100 Baud Rate : 19200 Enable Node Name Retention : Enabled PCI Latency Control : Long Frame Control : 2 KB Ctlr 0 Port 0 Ctlr 0 Port 1 : N/A Ctlr 1 Port 0 Ctlr 1 Port 1 : N/A...
  • Page 16: Simplex Configuration

    FFx-RAID Controller Parameter Settings Configuring the FFx-RAID Ctlr. 2.2.1 Simplex Configuration ATTENTION! Not all parameters can be accessed through the SAM software. Ê Display the SAM Controller Information window (figure 3) by clicking Admin- istration/Controller Information on the menu bar or the Controller Information icon.
  • Page 17 Configuring the FFx-RAID Ctlr. FFx-RAID Controller Parameter Settings For more information see “Setting and Modifying Controller Options” in the SAM documentation. Figure 4: SAM Basic Controller Options Dialog Box (simplex) Ê Open the Basic dialog box and set the parameters as shown in figure 4. Figure 5: SAM Advanced Controller Options Dialog Box (simplex) P15355-P111-Z139-5-7619...
  • Page 18 FFx-RAID Controller Parameter Settings Configuring the FFx-RAID Ctlr. Ê Open the Advanced dialog box and set the parameters as shown in figure 5. Figure 6: SAM Expert Controller Options Dialog Box (simplex) Ê Open the Expert dialog box and set the parameters as shown in figure 6. Figure 7: SAM Fibre Controller Options Dialog Box (simplex) P15355-P111-Z139-5-7619...
  • Page 19: Dual Active Configuration

    Configuring the FFx-RAID Ctlr. FFx-RAID Controller Parameter Settings Ê Open the Fibre dialog box and set the parameters as shown in figure 7. 2.2.2 Dual Active Configuration Use the same procedure for setting the controller parameter in a dual active configuration as shown in the figures below.
  • Page 20 FFx-RAID Controller Parameter Settings Configuring the FFx-RAID Ctlr. Figure 9: SAM Basic Controller Options Dialog Box (dual active) Figure 10: SAM Advanced Controller Options Dialog Box (dual active) P15355-P111-Z139-5-7619...
  • Page 21 Configuring the FFx-RAID Ctlr. FFx-RAID Controller Parameter Settings Figure 11: SAM Expert Controller Options Dialog Box (dual active) Figure 12: SAM Fibre Controller Options Dialog Box (dual active) P15355-P111-Z139-5-7619...
  • Page 22: San Mapping Tab

    9 on page 51) must be set to 1. The LUN per Target (parameter 1.5.4 in table 6 on page 50) must be set to the number of LUNs configured in the PRIMERGY S60 (maximum 32) when booting from a FFx-RAID controller.
  • Page 23: Configurations

    Configurations The FFx-RAID controllers use RAID technology to provide protection against drive failures. The FFx-RAID controllers also support configurations that employ multiple hosts and redundant controllers for improved fault-tolerance and high- performance data through-put. This chapter provides examples of non- clustering and cluster server single and dual-active controller configurations in host cabling topologies.
  • Page 24: Non Cluster Configurations

    ● to 10 km), requires HUB or switch with one MMF GBIC and one SMF GBIC, MMF HBA for the server and SMF GBIC plugged into the PRIMERGY S60 ● SMF connections between HUB or switch and PRIMERGY S60 are also...
  • Page 25 Configurations Non Cluster Configurations Figure 15: Direct Attached Storage Subsystem P15355-P111-Z139-5-7619...
  • Page 26: Direct Attached With Controller Fail Over

    ● host connector with MMF (up to 500 m), MMF HBA and GBIC with MMF interface plugged into the PRIMERGY S60 necessary ● copper cable (3 m) with HSSDC connector for FFx-RAID controller module to module connection optional use of MMF cables (up to 500 m) with MMF HBA and one MMF ●...
  • Page 27 Configurations Non Cluster Configurations Figure 16: Direct Attached Storage Subsystem with Controller Fail Over P15355-P111-Z139-5-7619...
  • Page 28: Path Redundancy Configurations

    (up to 10 m) are ● preferred, no GBIC needed ● optional use of MMF cables (up to 500 m) with MMF HBA and two MMF GBIC plugged into the PRIMERGY S60 Configuration hints ● Fibre-Topology: Multi Port ●...
  • Page 29 Configurations Path Redundancy Configurations Figure 17: Path Redundancy with Dual FFx-RAID Controller P15355-P111-Z139-5-7619...
  • Page 30: Path Redundancy With Single Ffx-Raid Controller

    (up to 10 m) are ● preferred, one copper GBIC needed ● optional use of MMF cables (up to 500 m) with MMF HBAs, one MMF GBIC and MIA plugged into the PRIMERGY S60 Configuration hints ● Fibre-Topology: - ●...
  • Page 31 Configurations Path Redundancy Configurations Figure 18: Path Redundancy with Single FFx-RAID Controller P15355-P111-Z139-5-7619...
  • Page 32: Multipath And Duplexwrite

    MMF cables (up to 500 m) between server with MMF HBA ● and PRIMERGY S60, two MMF GBIC necessary instead of copper GBICs plugged into the PRIMERGY S60. Copper cables for PRIMERGY S60 to PRIMERGY S60 connection are still used DuplexDataManager (MultiPath and DuplexWrite) necessary ●...
  • Page 33 Configurations Path Redundancy Configurations Figure 19: MultiPath and DuplexWrite P15355-P111-Z139-5-7619...
  • Page 34: Cluster Configurations

    (up to 10 m) are preferred, one copper GBIC needed ● optional use of MMF cables (up to 500 m) with MMF HBAs and one MMF GBIC plugged into the PRIMERGY S60. FFx configuration hints ● Fibre-Topology: - ●...
  • Page 35 Configurations Cluster Configurations Figure 20: Entry Cluster P15355-P111-Z139-5-7619...
  • Page 36: Entry Cluster With Redundant Dual Raid Controller

    Linux Cluster with Reliant Cluster in preparation (no SAM server/driver ● available) for rack internal connections low cost copper cables (up to 10 m) are ● preferred, one copper GBIC at PRIMERGY S60 is needed FFx configuration hints Fibre-Topology: Multi-TID ● Loop IDs (see figure 21 on page 30) ●...
  • Page 37: Entry Cluster With Dual Raid Controller

    Configurations Cluster Configurations 3.3.3 Entry Cluster with Dual RAID Controller Description no path redundancy ● Microsoft Cluster released and certified ● ● Linux Cluster with Reliant Cluster in preparation (no SAM server/driver available) for rack internal connections low cost copper cables (up to 10 m) are ●...
  • Page 38: Cluster With Duplexwrite

    Cluster Configurations Configurations 3.3.4 Cluster with DuplexWrite Description Microsoft Cluster released and certified ● for rack internal connections low cost copper cables (up to 10 m) are ● preferred, two copper GBICs needed DuplexDataManager (DuplexWrite) needed ● FFx configuration hints Fibre-Topology: - ●...
  • Page 39 Configurations Cluster Configurations Figure 23: Cluster with DuplexWrite P15355-P111-Z139-5-7619...
  • Page 40: Cluster With Multipath

    Cluster Configurations Configurations 3.3.5 Cluster with MultiPath Description Microsoft Cluster released and certified ● for rack internal connections low cost copper cables (up to 10 m) are ● preferred, two copper GBICs needed DuplexDataManager (MultiPath) necessary ● FFx configuration hints Fibre-Topology: Multi-Port ●...
  • Page 41 Configurations Cluster Configurations Figure 24: Cluster with MultiPath P15355-P111-Z139-5-7619...
  • Page 42: Cluster With Multipath And Duplexwrite

    LUN Mapping: affinity to all ports, enable all hosts or configure as needed ● optional use MMF cables (up to 500 m) with MMF HBA and MMF GBIC ● plugged into the PRIMERGY S60 DuplexDataManager (MultiPath and DuplexWrite) necessary ● P15355-P111-Z139-5-7619...
  • Page 43 Configurations Cluster Configurations Figure 25: Cluster with MultiPath and DuplexWrite P15355-P111-Z139-5-7619...
  • Page 44: Cluster With Multipath And Duplexwrite In A Switch Configuration

    LUN Mapping: affinity to all ports, enable all hosts or configure as needed ● optional use MMF cables (up to 500 m) with MMF HBA and MMF GBIC ● plugged into the PRIMERGY S60 ● DuplexDataManager (MultiPath and DuplexWrite) necessary ●...
  • Page 45 Configurations Cluster Configurations Figure 26: Cluster with MultiPath and DuplexWrite in a Switch Configuration P15355-P111-Z139-5-7619...
  • Page 46: San Mapping Configurations

    SAN Mapping Configurations Configurations SAN Mapping Configurations 3.4.1 SAN Mapping without External HUB/Switch Configuration hints ● Fibre-Topology: - ● Loop IDs (see figure 27 on page 40) ● LUN affinity as needed Figure 27: SAN Mapping without External HUB/Switch P15355-P111-Z139-5-7619...
  • Page 47: Standard San Mapping In Switch Configuration

    Configurations SAN Mapping Configurations 3.4.2 Standard SAN Mapping in Switch Configuration Configuration hints Fibre-Topology: - ● LUN Mapping: affinity to C0P0, host-to-LUN-mapping ● ● up to four PRIMERGY servers are released in configurations with switches MMF is the preferred connection medium ●...
  • Page 48 SAN Mapping Configurations Configurations Figure 28: Standard SAN Mapping in Switch Configuration P15355-P111-Z139-5-7619...
  • Page 49: San Mapping With Controller Fail Over In Switch Configuration

    SAN Mapping with Controller Fail Over in Switch Configuration PRIMERGY S60 configurations with both FFx-RAID controller in the same loop attached to a fibre channel switch can not be supported. Due to a technical modification of the mini HUB this configuration must be withdrawn.
  • Page 50 SAN Mapping Configurations Configurations Figure 29: SAN Mapping with MultiPath in Switch Configuration P15355-P111-Z139-5-7619...
  • Page 51: San Mapping With Multipath And Duplexwrite In Switch Configuration

    Configurations SAN Mapping Configurations 3.4.5 SAN Mapping with MultiPath and DuplexWrite in Switch Configuration Configuration hints Fibre-Topology: Multi Port ● ● LUN Mapping: affinity to all ports, host-to-LUN-mapping up to four PRIMERGY servers are released ● ● in configurations with switches MMF is the preferred connection medium DuplexDataManager (MultiPath and DuplexWrite) necessary ●...
  • Page 52 SAN Mapping Configurations Configurations Figure 30: SAN Mapping with MultiPath and DuplexWrite in Switch Configuration P15355-P111-Z139-5-7619...
  • Page 53: Appendix

    QLA2200 Fibre Channel HBA The settings described in this chapter are valid for QLA FW 1.61 only. Fujitsu Siemens Computers recommends configuring the Qlogic BIOS settings with the FSC-approved NVRAM settings file. This contains all the BIOS settings for the QLA2200 HBA that have been tested and approved for connection to storage subsystems (like PRIMERGY S60) in RAID configurations.
  • Page 54 Configuration Settings for QLA2200 Appendix 3. Select Configuration Settings (see table 1 on page 49) from the Fast!UTIL Options menu and press Enter Ú. 4. Select Extended Firmware Settings (submenu no. 1.6; see table 2 on page 49) from the Configuration Settings menu and press Enter Ú. 5.
  • Page 55: Fast!Util - Menus

    Appendix Configuration Settings for QLA2200 4.1.1 Fast!UTIL - Menus (QLA Bios 1.61, see FSC-Mailbox) Menu No. Fast!UTIL Options Configuration Settings Scan Fibre Devices Fibre Disk Utility Select Host Adapter Exit Fast!Util Table 1: Fast!UTIL Options menu Submenu Configuration Settings No. 1 Host Adapter Settings Selectable Boot Settings Restore Default Settings...
  • Page 56 Configuration Settings for QLA2200 Appendix Submenu Selectable Boot Settings Options Default No. 1.2 1.2.1 Selectable Boot Device disabled 1.2.2 Current Boot Node Name (see table 5 0000000000000000 below) 1.2.3 Current Boot LUN Number Table 4: Selectable Boot Settings submenu Submenu Host Adapter Settings No.
  • Page 57 Appendix Configuration Settings for QLA2200 Submenu Advanced Adapter Settings Options Default No. 1.5 1.5.13 IOCB Allocations 0-512 1.5.14 Extended Error Login disabled Table 6: Advanced Adapter Settings submenu Submenu LUN per Target Option No. 1.5.4 Value 1.5.4.1 QLA2200 is running on a WINNT4.0/WIN2000 system platform 1.5.4.2 QLA2200 is running on a system platform other than...
  • Page 58 Configuration Settings for QLA2200 Appendix Submenu Extended Firmware Settings Options Default No. 1.6 1.6.3 Connection Options (see also section “Qlogic Loop Only Configuration Hints” on Point to Point Only page 16) Loop Preferred, otherwise Point to Point Point to Point, otherwise Loop 1.6.4 NonParticipating Hard ID...
  • Page 59: Abbreviations

    Abbreviations Disk Array Controller DuplexDataManager Fiber Channel GBIC Gigabit Interface Converter Host Bus Adapter HSSDC High Speed Serial Direct Connect Logical Unit Number Multi Mode Fibre RAID Redundant Arrays of Independent Disks SAN Array Manager SCSI Small Computer System Interface Single Mode Fibre P15355-P111-Z139-5-7619...
  • Page 61: Related Publications

    Installation Guide and User Manual Global Array Manager™ Server Software Installation Guide and User Manual SANArray Manager™ Client Software Installation Guide and User Manual Embedded Configuration Utility User’s Guide PRIMERGY S60 Server Subsystem Operating Manual Hardware Installation Guide for the QLA2200/2200F/2202F P15355-P111-Z139-5-7619...
  • Page 63: Index

    Index cluster 28 MultiPath 26, 34, 36, 38, 43 configuration 17 cluster 28 parameter non cluster 18 Fx-RAID controller 8 path redundancy 22 settings 8 SAN mapping 40 PortDownRetryCount 47 with switch 38, 41, 43, 45 QLA2200 DuplexData Manager 26, 36, 38, 43, adapter topology 47 configuration 47 DuplexWrite 26, 36, 38, 45...
  • Page 65 Fujitsu Siemens Computers GmbH Comments User Documentation 81730 M ünchen Suggestions Germany Corrections Fax: (++49) 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on PRIMERGY S60 Storage Subsystem P15355-P111-Z139-5-7619...
  • Page 67 Fujitsu Siemens Computers GmbH Comments User Documentation 81730 M ünchen Suggestions Germany Corrections Fax: (++49) 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on PRIMERGY S60 Storage Subsystem P15355-P111-Z139-5-7619...
  • Page 69 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.