CAUTION! This is a Caution symbol. This symbol is used throughout the user guide whenever there is a risk of damaging your Lincat product. Ensure that these warnings are read and understood at all times. NOTE: This is a Note symbol.
Guarantee card SERIAL NUMBER Each appliance manufactured at Lincat has a unique identifying number found in the top right hand corner of NOTE the data plate attached at the rear of the appliance. Please record that number in the space provided should it be required for future reference.
MARK OF CONFIDENCE Every singe product that leaves our factory bears a serial plate showing the assembler‟s initials. It‟s a mark of confidence we have in our people and our manufacturing process. Component Identification Wire basket support Knurled fastener Thermostat Control Right element on Power on Left element on...
OE7113/F COMPONENT IDENTIFICATION Component Identification Wire basket support Knurled fastener Element on Power on Thermostat Control Pump on Operating mode LH limit reset Pump reset RH limit reset Oil bucket Filter bag cover Filter pad connection Drain valve Tank selector OE7105/F COMPONENT IDENTIFICATION INSTALLATION PREPARATION...
This appliance must be connected to the electricity supply by a qualified electrician, in accordance with relevant regulations. This appliance should be connected to mains electricity via a suitable isolating switch, which should have at least a 3mm contact separation on all poles. ...
Page 8
OPERATIONAL CHECK Although all Lincat fryers are functionally checked during manufacture, commissioning must include a functional check of all controls. FRYER MODE Set the thermostat to 190 C and allow the oil to heat up. Use a suitable device to check that the temperature of the oil. At a position 25mm below the surface of the oil, at the geometric centre of the tank, the oil temperature should be within +/- C of the set temperature.
SERVICING ROUTINE SERVICE We recommend that all servicing, other than routine cleaning, be carried out by our authorised service agents. Carry out a general check on the installation paying particular attention to the following:- o Is the unit installed with the correct rating of cable. o Is it connected to the supply via a suitable isolating switch.
Page 10
Raise the elements using the element raising hook. Unclip the thermocouple phial and the capillary tube from the element legs. Unhook the coiled capillary from around the capillary support tube. Reassemble in reverse order. Ensure that the coil diameter around the capillary support tube is 15-20mm diameter and that a left hand or right hand coil of 4 turns is formed, depending on which side of the unit it is being fitted to.
Isolate the unit from the mains supply. Remove the rear panel, door/s and the left side panel Undo the control panel and support. Disconnect the pump inlet and outlet pipes. Remove the live, neutral and earth connections. ...
FAULT FINDING Fryer will not heat up Check the mains Is the green neon isolator and fuse illuminated on the Check unit is in fryer front facia mode. Is the thermostat Turn on the turned on thermostat Is the amber light Check if the limit stat needs resetting Is the contactor...
Page 13
Filtration pump will not work Is the unit in fryer Switch the unit into mode (green neon filter mode. Has the pump Reset thermal trip motor thermal See below trip activated Is the filtration return Correctly fit the filtration pipe correctly fitted return pipe to the quick coupling Is the filter...
1.5 kg Never operate the pump without the carbon filter pad fitted into the pad holder. Always use the correct filter pad. Lincat part number OA7937 (30 pack) FILL WITH OIL Remove the dust cover and locate it behind the wire basket support at the rear of the tanks.
Page 16
WARNING HOT OIL – Wear protective clothing, gloves and safety glasses. Do not operate the filtration system without a filter pad fitted to the filter pad holder. FILTERING, OIL CHANGE AND CLEANING INSTRUCTIONS On the OE7113/F and OE7105/F models, drain and filter one tank at a time. A small amount of oil will remain in the bottom of the drain tank.
Page 17
Open the fryer doors and fit the supplied drain tube ensuring it is pointing into the container. Please stand your empty oil container in a tray as this will help prevent any spillages or drips on the floor. ...
Catering equipment should be routinely serviced to ensure a long trouble free life. It is recommended that this appliance is serviced every 6 months by a competent engineer. For help regarding the installation, maintenance and use of your LINCAT equipment, please call:- LINCAT SERVICE HELP DESK ...
Need help?
Do you have a question about the OE7105 F and is the answer not in the manual?
Questions and answers