Diagram Of Aquastar - Bosch AquaStar 125X LP Installation And Operating Instructions Manual

Bosch automatic instantaneous type water heaters for use with natural and liquefied petroleum gas (flow modulated with electronic ignition) suitable for heating potable water only not approved for space heating purposes
Table of Contents

Advertisement

2. Cold water is mixing with the hot water between
the AquaStar and the outlet
See #4 under "NO SPARK AT THE PILOT".
3.
Inlet water pressure is erratic due to
inadequate supply water pressure or saturated
pressure tank on well system
Check the inlet water pressure. On a private well, raise
minimum pressure setting to 30 psi. Confirm that the
pressure tank is not water logged.
4. Gas pressure is too low
See page 2 and 7 for correct specifications.
3
2
5
6
7
8
11
1.
Heat exchanger
2.
Pilot assembly
3.
Burner manifold gas
pressure test nipple
4.
Main gas burner
5.
Pilot gas tubing
6.
Gas valve
Diagram of AquaStar 125 X
Fig. 14 -
7.
Electronic control box
8.
Battery box
9.
on/off switch
10.
Temperature adjustment selector
11.
Microswitch
12.
Gas inlet gas pressure test nipple
13.
LED
1
4
9
13
10
12
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquastar 125x ng

Table of Contents