Checking Timecode And The Remaining Tape Time; Checking The Power Voltage And Selecting The Fan Mode - Sony SRW-9000 Operation Manual

Hd camcorder/hd-sdi expansion board/rgb 4:4:4processor board
Hide thumbs Also See for SRW-9000:
Table of Contents

Advertisement

Checking Timecode and the
Remaining Tape Time
The timecode/tape remaining page allows you to
check timecode and the approximate remaining
tape time (unit: minutes).
Timecode/tape remaining page
The first line displays a timecode value, and the
second line displays the approximate tape
remaining time, within the range 1 to 99 minutes.
The following table lists the types of timecode
that appear.
Indication
Meaning
TCR 00:00:00:00
Timecode data of the LTC
reader
TCR 00:00.00:00
Timecode data of the LTC
reader (DF)
TCR.00:00:00:00
Timecode data of the VITC
reader
UBR 00 00 00 00
User bit data of the LTC
reader
UBR.00 00 00 00
User bit data of the VITC
reader
TCG 00:00:00:00
Timecode data of the
timecode generator
TCG 00:00:00.00
Timecode data of the
timecode generator (DF)
UBG 00 00 00 00
User bit data of the timecode
generator
CTL -0:00:00:00
Data of the CTL counter
T*R 00:00:00:00
Timecode cannot be read with
the LTC reader.
U*R 00 00 00 00
User bits cannot be read with
the LTC reader.
T*R.00:00:00:00
Timecode cannot be read with
the VITC reader.
U*R.00 00 00 00 User bits cannot be read
with the VITC reader.
See "To select time data to display during playback"
(page 85) for information about how to switch
between different types of timecode.
Checking the Power Voltage and
Selecting the Fan Mode
Voltage check/Fan mode page
The first line allows you to check the battery
voltage, and the second line displays the
operating mode of the internal fans.
To select the fan mode
You can select the fan mode from the modes in
the following table.
Setting
Operation of the fans
AUTO1 (default)
The fans are controlled
automatically according to the
unit's internal temperature.
During recording, they are
controlled for quiet operation.
Normally use this mode.
AUTO2
Normally the fans are
controlled in the same way as
in MIN mode, but during
recording they are controlled
for quieter operation.
However, control for quieter
operation is limited to several
minutes or less.
Use this mode only when the
ambient temperature is normal
or lower.
MIN
In this mode, the fans operate
quietly regardless of whether
the unit is recording. This
mode is preferable for 30
minutes or more of shooting
in quiet environments such as
concert halls.
Use this mode only when the
ambient temperature is normal
or lower.
MAX
The fans rotate at maximum
speed to lower the unit's
internal temperature.
Notes
• If the internal temperature rises so high that the
TEMPERATURE CARE message is displayed, the
fan rotation speed will automatically increase to lower
the temperature.
Basic Settings with the Subdisplay