Omron IntelliSense HEM-907 Instruction Manual
Omron IntelliSense HEM-907 Instruction Manual

Omron IntelliSense HEM-907 Instruction Manual

Intellisense
Hide thumbs Also See for IntelliSense HEM-907:

Advertisement

OMRON
IntelliSense™ Blood Pressure Monitor
HEM-907
Model
INSTRUCTION MANUAL
Thank you very much for purchasing the
OMRON IntelliSense™ Blood Pressure Monitor.
Please thoroughly read this Instruction Manual
before using this monitor to insure safe and
accurate use.
Please keep this manual near the monitor all
the time for future reference.
This Instruction Manual contains the Quality
Guarantee Card.

Table of Contents

Be Sure to Read This Section
Exemptions ........................................2
Notes on Safety..................................3
Know Your Unit
Features of the Product......................7
Components of the Product ...............8
Options ...........................................9
Names of the Parts.......................10
while the unit is in use ..................12
Preparations before Measurement
How to Apply the Cuff ......................14
of Battery Pack .............................17
SINGLE Mode ..............................20
AVG Mode ....................................22
MANU Mode .................................24
List of Error Codes ...........................28
Troubleshooting ...............................29
Specifications
Caution.............................................30
Specifications ...................................31
16
............

Advertisement

Table of Contents
loading

Summary of Contents for Omron IntelliSense HEM-907

  • Page 1: Table Of Contents

    Model INSTRUCTION MANUAL Table of Contents Thank you very much for purchasing the Be Sure to Read This Section OMRON IntelliSense™ Blood Pressure Monitor. Exemptions ........2 Notes on Safety........3 Please thoroughly read this Instruction Manual Know Your Unit before using this monitor to insure safe and accurate use.
  • Page 2: Exemptions

    2. We have prepared the contents of this Instruction Manual thoroughly. However, if an inadequate description or error is found, please let us know. 3. Reproducing or copying any or all of this Instruction Manual without OMRON’s written consent is prohibited.
  • Page 3: Notes On Safety

    Notes on Safety • The warning signs and the sample icons shown here are listed to insure safe and accurate use. • The icons and meanings are as follows. Warning sign Contents Indicates matters in which death or severe bodily damage may arise as a result of incorrect handling.
  • Page 4 After cleaning this unit, dry it well before plugging the AC adapter in the electric outlet. If this unit fails to perform as indicated, discontinue use, turn off the unit, unplug the AC adapter from the electric outlet, and contact OMRON’s repair department. Do not disassemble or modify this unit.
  • Page 5 Notes on Safety Do not use a cellular phone near this unit. Do not use this unit in a vehicle. Do not install the parts and/or instruments not specified for this unit. Do not use a broken power cord or AC adapter. Do not install or store this unit where it may come in contact with water or liquid medication.
  • Page 6 (1) Remove the cuff from the patient's arm. (2) Turn off the power of the unit and unplug the AC adapter from the electric outlet. (3) Display "Out of use" on this unit so that it cannot be used. (4) Contact Omron repair service (1-877-216-1336).
  • Page 7: Features Of The Product

    Features of the Product OMRON IntelliSense™ Blood Pressure unit, Model HEM-907 is developed to measure blood pressure and pulse rate accurately and simply in a doctor's office, examination room, or patient bedside. • One-button operation Simply wrap the cuff and push the START Button. Blood pressure and pulse rate are automatically measured by the oscillometric method.
  • Page 8: Components Of The Product

    Components of the Product Main unit IntelliSense™ Blood Pressure Monitor, Model HEM-907 Accessories (Included and also available separately) Cuff / bladder set Large Cuff / bladder set Medium Cuff / bladder set Small (with built-in bladder) * (with built-in bladder) *...
  • Page 9: Options

    Components of the Product Options (not included) Cuffs without bladder * Bladders * Large Cuff Large Bladder Model:HEM-907-CUFFL Model: HEM-907-BLDRL Medium Bladder Medium Cuff Model: HEM-907-BLDRM Model: HEM-907-CUFFM Small Bladder Small Cuff Model: HEM-907-BLDRS Model: HEM-907-CUFFS Air tube 1.3 m *(51 1/6")
  • Page 10: Names And Functions Of The Parts

    Features and Functions Names of the Parts Main unit 1. Display (See Page 11 for detail) 6. ON/OFF (power) Button 2. HIDE (non-display) Button 7. START Button 8. DEFLATION (deflation control) /Measurement Result Display Switch Button 3. DC jack 9. Air Connector 4.
  • Page 11: Features And Functions

    Features and Functions Display Systolic blood pressure Ready to Measure / Pulse synchronization Diastolic blood pressure Pulse level / Number of irregular pulses Number of irregular pulse waves: The pulse wave having a difference of more than 25% from the average interval of pulse waves is determined irregular.
  • Page 12: Functions And Setting

    Features and Functions Functions setting (1) Inflation level setting AUTO (Automatic setting): Can be used when the SINGLE, AVG, or MANU Mode is selected. The unit estimates the systolic blood pressure during inflation and inflates to a proper cuff pressure (approximately 30-40 mmHg above the patient’s systolic pressure).
  • Page 13 Features and Functions List of Functions for each Mode Measurement Single (SINGLE) Average Auscultation Check Mode Mode (AVG) Mode (MANU) Mode (CHECK) Mode Function Inflation level setting Non-display function Manual deflation control (4) AVG Function setting You can set the number of measurements, the waiting time until the 1st measurement, and the measurement interval for the AVG Mode.
  • Page 14: How To Apply The Cuff

    How to Apply the Cuff The cuff of OMRON IntelliSense™ Blood Pressure Monitor HEM-907 plays an important role of collecting the information on blood vessels. Please wrap the cuff according to the procedure, below. General advice • Do not inflate the cuff without being wrapped over Do not wrap the cuff over on arm to which the arm.
  • Page 15 How to Apply the Cuff 3. Place the hand of the patient with the palm of hand facing upward. 4. Align the Artery Position Mark with the brachial artery. 5. Wrap the cuff snugly using both hands and securely fasten it with the Velcro™ tape.
  • Page 16: How To Use The Power Source

    How to Use the Power Source How to use the AC adapter Be sure to use the AC adapter from the power Do not use this unit in the presence of flammable gas, or anesthetics, or in a high supply of 110 VAC. pressure oxygen room or oxygen tent.
  • Page 17: Installation And Replacement Of Battery Pack

    How to Use the Power Source Installation and Replacement of Battery Pack (option) If battery fluid gets into your eye or comes in contact with skin, wash the affected area with water repeatedly. Immediately consult a doctor for treatment. Do not use the battery pack for devices other than for this unit.
  • Page 18 How to Use the Power Source Battery life • You can use the unit for approximately three hundred measurements with one charge. • Approximate life of battery is two years. However the battery life from each charging may be shortened depending on the state of using. If the interval between charging becomes short and mark appears frequently, replace it.
  • Page 19: How To Measure Blood Pressure

    How to Measure Blood Pressure Confirm readings with the stethoscope when If cuff inflation does not stop, remove the cuff an irregular pulse wave is displayed or when or pull out the air tube from the main unit. the measured value is questionable or erratic. General advice Do not use a cellular phone near this unit.
  • Page 20: Single Mode

    How to Measure Blood Pressure (in SINGLE Mode) 1. Push the ON/OFF (power) Button to turn on the power. 2. Set the MODE Selector to "SINGLE". 3. Set the P-SET (inflation level) Knob to "AUTO" or to the target pressure value.
  • Page 21 How to Measure Blood Pressure (in SINGLE Mode) 5. Push the START Button to start the measurement. • Do not push the START Button without wrapping the cuff. • If you want to stop measurement, push the STOP Button. The cuff will rapidly deflate.
  • Page 22: Avg Mode

    How to Measure Blood Pressure (in AVG Mode) 1. Push the ON/OFF (power) Button to turn on the power. 2. Set the MODE Selector to "AVG". The factory-set values are set as follows: • Number of measurements: 2 • Waiting time until the 1st measurement: 0 sec. •...
  • Page 23 How to Measure Blood Pressure (in AVG Mode) 5. Push the START Button to start the measurement. After the pre-select waiting time, the unit takes the 1st measurement. After displaying the results of 1st measurement, subsequent measures occur automatically at the specified intervals. •...
  • Page 24: Manu Mode

    How to Measure Blood Pressure (in MANU Mode) 1. Push the ON/OFF (power) Button to turn on the power. 2. Set the MODE Selector to "MANU". 3. Set the P-SET (inflation level setting) Knob to "AUTO" or the target pressure value. 4.
  • Page 25 How to Measure Blood Pressure (in MANU Mode) 5. Place the stethoscope on the patient's arm. 6. Push the START Button to start the measurement. • Do not push the START Button without wrapping the cuff. • Do not squeeze or press the cuff during the measurement.
  • Page 26: How To Check Pressure Accuracy

    7. Compare the pressure values displayed on the monitor to the one on the manometer. Check result Accuracy of the monitor is controlled by ±3 mmHg or 2% of standard manometer reading. If your result shows a difference exceeding the tolerance, contact Omron repair department (1-877-216-1336).
  • Page 27: How To Clean The Unit After Use

    How to Clean the Unit after Use General advice When cleaning this unit, unplug the AC • Do not clean this unit with gasoline, paint thinner, or adapter from the electric outlet. high concentration alcohol. • Do not disinfect this unit by autoclave or gas sterilization (EtO, gluteraldehyde, or high After cleaning this unit, dry it well, before concentration ozone.)
  • Page 28: List Of Error Codes

    • Check the patient for arrhythmia. • Pulse rate did not stay within the range of 30 to 199 beats/min. Device error • Contact Omron’s repair department toll-free at • This is a trouble of the main unit of the (1-877-216-1336). monitor.
  • Page 29: Troubleshooting

    Troubleshooting If the unit malfunctions during use, please check the following: Trouble What to inspect How to correct Wrap the cuff correctly, and Is the cuff wrapped correctly? measure again. (Refer to Page 14 and 15.) Ask the patient not to move Is the patient moving during The unit inflates to during measurement, and...
  • Page 30: Caution

    Caution CAUTION: Changes or modifications not expressly approved by Omron Healthcare, Inc. could void the user’s authority to operate this product. NOTE: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules.
  • Page 31: Five Year Limited Warranty

    Five Year Limited Warranty Your HEM-907 IntelliSense™ Automatic Blood Pressure Monitor is warranted to be free from manufacturing defects for a period of five years under normal use. The five year warranty excludes the monitor cuff. The cuff is warranted for a one year period. This warranty extends only to the original retail purchaser.
  • Page 32 For Customer Service Call Toll Free 1-877-216-1336 Manufactured by OMRON Distributed by: OMRON HEALTHCARE, INC. 300 Lakeview Parkway Vernon Hills, Illinois 60061 www.omronhealthcare.com Copyright © 2000 OMRON HEALTHCARE, INC. HEM-907INST...

Table of Contents