3. Setting Heat Cycle Rate (see Table 2 for cycle rate
options and equipment).
a.
Press the ▲ key to
display the current
heat cycle rate
setting of 3, 4, 5, 6,
9 or 12 cph.
b.
If the desired cycle
rate is displayed,
press the ▲ key to
exit the installer
setup.
c.
To change the
heat cycle rate,
press the ▼ key until your choice of 3, 4, 5, 6,
9 or 12 is displayed.
d.
Press the ▲ key to
display cooling
algorithm configu-
ration default.
Press the ▲ key
e.
again to change
cooling algorithm to C1 or C3.
C1 = Standard cooling algorithm.
C3 = Agressive cooling algorithm (can
cause overshooting).
Press the ▲ key again. Current configuration
f.
(CC) is displayed. A typical example is shown,
but CC varies by
model. (This
information is for
factory use only.)
4. Exit Installer Setup.
a.
Press
the ▲
key to
save all
changes
and
return to
normal

operation.

Table 2. Heating Cycle Rate
System
Hydronic Heat, Condensing
a
Gas Furnaces
Gas or Oil Forced Air
Electric Heat
b
Special Applications
a
High efficiency furnace (90+).
b
Refer to the equipment manufacturer's Instructions.
NOTE: Stage one heat and cool cycle rates are fixed at
3 cph. Only stage two heat cycle rates are
selectable.
T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT
M12588A
M12589A
M14691
M14692
PM
M12590A
Cycles Per Hour
3
6
9
12
4, 5, 12
5
OPERATION

Setting FAN and SYSTEM Switches

Fan and system settings are controlled manually by using
the switches located at the bottom of the
thermostat case. See Fig. 7.

FAN Switch

Fan switch settings are:
On: The fan runs continuously. Use for improved air
circulation and air quality.
Auto: Normal setting for most homes. The fan starts
and stops with the equipment.
Slide the FAN switch in the lower left corner of the
thermostat to select the desired fan setting.

SYSTEM Switch

System switch settings control thermostat operation as
follows:
Cool: The thermostat controls the cooling system.
Off: Both heating and cooling are off.
Heat: The thermostat controls the heating system.
Em. Ht.: The thermostat cycles auxiliary heat (W2) and
emergency heat relay (E) as needed to maintain
setpoint. Terminal L is energized continuously (fault
heat relay is on continuously). Cooling system is off.
Compressor is de-energized.
Slide the SYSTEM switch in the lower right corner of the
thermostat to select the desired system setting.
T8011
Fig. 7. Digital Display and System Switches.
H o l d
S e l e
c t
M14700
69-1435–1