FRONT CABINET REMOVAL (Refer to Figures 2 and 3)
2. Take out the cassette tape from the cassette holder.
3. Remove eight (8) screws retaining the front cabinet.
4. Gently pull out the front cabinet and disconnect four (4)
q
OPERATION PANEL REMOVAL (Refer to Figure 3)
1. Remove the front cabinet as described in front cabinet
removal.
2. Remove seven (7) knobs (record level, bass, treble, volume
and fader).
3. Gently lift up the operation panel from the back cabinet.
removal.
2. Remove four (4) screws retaining the dial scale plate.
3. Gently pull out the dial scale plate from the chassis.
1. Remove the dial scale plate as described in dial scale plate
removal.
2. Disconnect the tip (muting) and two (2) sockets (Sol,
P.W. board.
3. Remove four (4) screws retaining the mechanism block.
4. Gently pull out the mechanism block from the main P.W.
board holder.
q
PHONO JACK PLATE REMOVAL (Refer to Figure 5)
1. Remove the mechanism block as described in mechanism
block removal.
2. Remove two (2) screws retaining the phono jack plate.
3. Gently pull out the phono jack plate from the back cabinet.
CHASSIS (P.W.B.) REMOVAL (Refer to Figure 5)
1. Remove the phono jack plate as described in phono jack
plate removal.
2. Remove two (2) knobs (tuning and fine tuning).
3. Disconnect three (3) tips (Antenna) and two (2) tips (DC
supply) connected to the main P.W. board.
4. Remove seven (7) screws retarning the chassis (P.W.B.).
5. Gently pull out the chassis (P.W.B.) from the back cabinet.