Troubleshooting > Trouble Diagnosis
REC button does not operate.
Set to service position (A).
No
TL7001(REC_KEY):
0V
(*1)
Yes
*1: When REC button is pressed
Replace the MAN
circuit board.
Zoom lever does not operate.
Yes
Can zoom be operated
by remote control?
No
No
Does autofocus operate?
Yes
Replace the MAN
circuit board.
List of check points
Circuit board
Symptom
(side)
TL7001
MAN (B)
REC button faulty:
Replace the rear case.
Zoom lever faulty:
Replace the rear case.
Refer to "Autofocus does
not operate".
4 - 34
Lead wire
Location on
soldered
circuit board
or not
5D
Need not