6) After the system has been charged with specified amount (350
– 450 g, 12.3 – 16.0 oz.) of refrigerant or when low and high pres-
sure gauges have indicated specified value below respectively,
close low pressure side valve of manifold gauge set.
Low pressure gauge when charged with specified amount
About 200 – 300 kPa (2 – 3 kg/cm
(At A/C inlet temperature 30 – 35 C, 86 – 95 F)
High pressure gauge when charged with specified amount
About 1370 – 1670 kPa (14 – 17 kg/cm
(At A/C inlet temperature 30 – 35 C, 86 – 95 F)
AIR CONDITIONING (OPTIONAL) 1B-5
2
, 29 – 43 psi)
2
, 200 – 244 psi)