Checking The Drives For Data Consistency - Asus ESC4000-FDR G2S User Manual

2u rackmount server
Table of Contents

Advertisement

6.2.5

Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected virtual drive. The
utility can automatically detect and/or detect and correct any differences in data redundancy
depending on the selected option in the Objects > Adapter menu.
The Check Consistency command is available only for virtual drives included in a RAID 1 or
RAID 10 set.
Using the Check Consistency Command
To check data consistency using the Check Consistency command
1.
From the Management Menu, select Check Consistency, and then press <Enter>.
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
2.
The screen displays the available RAID set(s) and prompts you to select the virtual
drive to check. Press <Space> to select the virtual drive from the Virtual Drive sub-
menu, and then press <F10>.
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
6-18
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version
Easy Configuration - ARRAY SELECTION MENU
LD
RAID
0
Virtual Drives
Virtual Drive 0
Select VD
SPACE-(De)Select, F10-Initialize
A.10.09231523R
CC of VD(s)
A.10.09231523R
Virtual Drive(s) Configured
Size
#Stripes
1
148.580GB
2
StripSz
Status
64KB
ONLINE
Chapter 6: RAID configuration

Advertisement

Table of Contents
loading

This manual is also suitable for:

Esc4000 g2s

Table of Contents