Motorola MVME167 Series Installation Manual page 137

Single board computer
Hide thumbs Also See for MVME167 Series:
Table of Contents

Advertisement

Table A-1. ENV Command Parameters (Continued)
ENV Parameter and Options
Auto Boot Abort Delay
Auto Boot Default String [NULL
for an empty string]
ROM Boot Enable [Y/N]
ROM Boot at power-up only
[Y/N]
ROM Boot Enable search of
VMEbus [Y/N]
ROM Boot Abort Delay
ROM Boot Direct Starting
Address
ROM Boot Direct Ending Address
Network Auto Boot Enable [Y/N]
Network Auto Boot at power-up
only [Y/N]
Setting Environment to Bug/Operating System
Default
Meaning of Default
15
This is the time in seconds that the
Auto Boot sequence will delay before
starting the boot. The purpose for the
delay is to allow you the option of
stopping the boot by use of the Break
key. The time value is from 0 through
255 seconds.
You may specify a string (Þlename)
which is passed on to the code being
booted. Maximum length is 16
characters. Default is the null string.
N
ROMboot function is disabled.
Y
ROMboot is attempted at power up
only.
N
VMEbus address space will not be
accessed by ROMboot.
0
This is the time in seconds that the
ROMboot sequence will delay before
starting the boot. The purpose for the
delay is to allow you the option of
stopping the boot by use of the Break
key. The time value is from 0 through
255 seconds.
FF800000
First location tested when the Bug
searches for a ROMboot Module.
FFBFFFFC Last location tested when the Bug
searches for a ROMboot Module.
N
Network Auto Boot function is
disabled.
Y
Network Auto Boot is attempted at
power up reset only.
A
A-5