Heater Clearances; Outside Vent Removal - Pentair Pool Products 175K BTU Operations & Installation Manual

120/240 vac natural gas/lp gas pool & spa heater
Table of Contents

Advertisement

Available languages

Available languages

1 8
INDOOR VENTING — General Requirements
The heater may be installed as a Category I or Category III appliance.
Vented Appliance (Category I)
An appliance that operates with a nonpositive vent static pressure and with a vent gas temperature that avoids excessive
condensate production in the vent, see
Vented Appliance (Category III)
An appliance that operates with a positive vent static pressure and with a vent gas temperature that avoids excessive
condensate production in the vent, see
If you are considering connecting this heater to a pre-existing vent system, make sure that the vent system meets the
appropriate venting requirements as given in this manual on
a draft hood with this heater.
The vent pipe must be the same size or larger. The MasterTemp heaters are capable of a 270-degree discharge rotation
and operate with a positive vent static pressure and with a vent gas temperature less than 400° F. The total length of the
horizontal run must not exceed the length that is listed in
HEATER CLEARANCES — General Requirements
INDOOR INSTALLATION (U.S.) OR OUTDOOR SHELTER (CANADA)
The following clearances must be maintained from combustible surfaces:
TOP .................................. 3 ft. (1 m)
EXHAUST SIDE .......... 6 in. (15 cm)
HEADER SIDE ............ 6 in. (15 cm)
DOOR PANELS† ........ 6 in. (15 cm)
Note (†) For service access it is advisable to allow for sufficient clearance
on at least one door panel. The heater is design certified by CSA International
for installation on combustible flooring. For installation on carpeting, the
heater must be mounted on a metal or wood panel that extends at least
three inches (10cm) beyond the base of the heater. If the heater is installed
in a closet or alcove, the entire floor shall be covered by the panel. On an
outdoor shelter installation, the exhaust discharges into a vent pipe. Orient
the heater so that the vent pipe does not interfere with adjustment of the
operating controls. The control panel located on the top panel can be rotated
to any of the three sides of the heater for easy access. However, the
control panel must not be located on the side where the vent is located.
OUTSIDE VENT COVER REMOVAL
The heater is supplied from the factory with a built-in stackless outside vent for outdoor installation. Remove the outside
vent cover for outdoor shelter installation.
P/N 472592
pages
20-22.
pages
23-25.
pages
table 11
on
18-27. If not, replace the vent system. DO NOT use
page
23.
For service access, it is advisable to allow for
sufficient clearance on at least one door panel.
6 in.*
Section 3. Installation
6 in.
6 in.*
6 in.
Figure 10.
Rev. B 3-7-07