Pacific AMX series Operation Manual page 153

Amx series ac power source
Table of Contents

Advertisement

The following lists changes to the manual. The information which follows takes precedence over that
originally given.
NOTE ON ETL LISTED SYSTEMS, Models 105, 108, 112, 305, 308, and 312-AMX:
An Input Power Cord plug is now provided since ETL/UL considers these models to be of the "portable"
class. Use of a UL listed plug is mandatory in maintaining listed status.
If the provided plug does not match the service outlet to be used, a UL listed plug of applicable voltage
form and current rating may be substituted (see paragraph 2.1.1 INPUT POWER REQUIREMENTS and
related errata in this document.)
NOTE ON ETL LISTED SYSTEMS, Models 125, 140, 345, 360, 390, and 3120-AMX:
The Input Terminal Block cover is now provided since ETL/UL considers these models to be of the
"permanently connected" class. Use of the cover is mandatory in maintaining listed status.
"Knock-outs" are provided for wiring to the Input Terminal Block.
PAGE 7; PARAGRAPH 2.1.1 INPUT POWER REQUIREMENTS, MODEL 105-AMX
PAGE 8; PARAGRAPH 2.1.1 INPUT POWER REQUIREMENTS, MODEL 108-AMX
PAGE 10; PARAGRAPH 2.1.1 INPUT POWER REQUIREMENTS, MODEL 305-AMX
PAGE 10; PARAGRAPH 2.1.1 INPUT POWER REQUIREMENTS, MODEL 308-AMX
Changes due to ETL listing and CE-mark requirements, all four models. Service Recommended matched
to Input Circuit Breaker amperage rating.
WAS:
1)
2)
IS:
1)
2)
PAGE 9; PARAGRAPH 2.1.1 INPUT POWER REQUIREMENTS, MODEL 140-AMX
PAGE 12; PARAGRAPH 2.1.1 INPUT POWER REQUIREMENTS, MODEL 345-AMX
Changes due to ETL listing and CE-mark, requirements, both models. Service Recommended matched to
Input Circuit Breaker amperage rating.
WAS:
1)
2)
3)
IS:
1)
2)
3)
ERRATA
FOR THE
AMX-SERIES OPERATION MANUAL
DOCUMENT 139250
Vin
110VAC
19 Arms; 20 A Service Recommended
120VAC
18 Arms; 20 A Service Recommended
Vin
110VAC
19 Arms; 25 A Service Recommended
120VAC
18 Arms; 25 A Service Recommended
Vin
208 VAC ∆
21 Arms; 30 A Service Recommended
220 VAC ∆
20 Arms; 30 A Service Recommended
240 VAC ∆
18 Arms; 30 A Service Recommended
Vin
208 VAC ∆
21 Arms; 40 A Service Recommended
220 VAC ∆
20 Arms; 40 A Service Recommended
240 VAC ∆
18 Arms; 40 A Service Recommended
E - 1
INPUT CURRENT
INPUT CURRENT
INPUT CURRENT
INPUT CURRENT
11/17/04