Radiator Fan Switch, Water Temperature Switch

Radiator Fan Switch Removal

Disconnect the fan switch leads [A].
Pull out the cover [B].
Remove the radiator fan switch [C].
The fan switch or the water temperature switch
should never be allowed to fall on a hard surface.
Such a shock to these parts can damage them.

Water Temperature Switch Removal

Drain the coolant (see Coolant Draining).
Remove the fuel tank (see Fuel Tank Removal in the Fuel
System chapter).
Unscrew the thermostat housing mounting bolts [A] and
flange bolts [B].
Pull the thermostat housing toward the rear.
Disconnect the switch lead connector [A].
Remove the switch [B].
Radiator Fan Switch, Water Temperature Switch
Installation
Apply silicone sealant to the threads before mounting the
water temperature switch.
Sealant - Kawasaki Bond (Silicone Sealant): 56019-120
Do not apply silicone sealant to the radiator fan switch on
the radiator.
Tighten the water temperature switch and the fan switch.
Torque - Water Temperature Switch: 7.8 N·m (0.80 kgf·m,
69 in·lb)
Radiator Fan Switch: 18 N·m (1.8 kgf·m, 13 ft·lb)
Radiator Fan Switch, Water Temperature Switch
Inspection
Refer to Radiator Fan Switch, Water Temperature Switch
Inspection in the Electrical System chapter for these in-
spections.
CAUTION
COOLING SYSTEM 3-17

Advertisement

Table of Contents

   Also See for Kawasaki EN500 Vulcan 500 LTD

This manual is also suitable for:

Vulcan 500 ltd

Comments to this Manuals

Symbols: 0
Latest comments:
  • Ricardo Paluan Apr 27, 2016 01:22:
    Adquiri recentemen​te uma moto vulcan 500 ano 1995. Tenho o 37 anos e iniciante no mundo motociclis​ta. Entretanto​, em razão só tempo e idade da moto, não tenho o manual do proprietá​rio, sendo este indispens