Download  Print this page

Pump Impeller Inspection; Mechanical Seal Inspection - Kawasaki EN500 Vulcan 500 LTD Service Manual

Motorcycle.
Hide thumbs

Advertisement

Water Pump

Pump Impeller Inspection

Visually check the impeller [A].
If the surface is corroded, or if the blades are damaged,
replace the impeller.

Mechanical Seal Inspection

Visually inspect the mechanical seal.
If any one of the parts is damaged, replace the mechani-
cal seal as a unit.
The sealing seat and rubber seal may be removed easily
by hand.
[A] Impeller Sealing Seat Surface
[B] Rubber Seal
[C] Mechanical Seal Diaphragm
COOLING SYSTEM 3-11