Ignition System
IC Igniter Internal Resistance (4P)
Terminal
1
1
2
(–)*
3
4
(–)*: Tester (–) Lead Connection
IC Igniter Internal Resistance (8P)
Terminal
5
35 ∼ 200
6
7 ∼ 28
7
4.2 ∼ 18
8
(–)*
9
10
11
1.4 ∼ 6
12
(−)*: Tester (−) Lead Connection

Diodes Inspection

Remove the meter instruments (see Meter Instruments
Removal).
Disconnect the diode assemblies [A].
Zero the hand tester, and connect it to each diode terminal
to check the resistance in both directions.
The resistance should be low in one direction and more
than ten times as much in the other direction. If any diode
shows low or high in both directions, the diode is defective
and the diode assembly must be replaced.
The actual meter reading varies with the meter used
and the individual diode, but, generally speaking, the
lower reading should be from zero to one half the scale.
Tester (+) Lead Connection
2
3
0 ∼ 0.8
0 ∼ 0.8
26 ∼ 150
26 ∼ 150
5
6
22 ∼ 90
7 ∼ 30
4.6 ∼ 19
1.8 ∼ 7.5
1.6 ∼ 7
1.8 ∼ 8
NOTE
ELECTRICAL SYSTEM 15-43
Unit: kΩ
4
28 ∼ 150
30 ∼ 150
Tester (+) Lead Connection
7
8
20 ∼ 80
35 ∼ 200
1.8 ∼ 8
7 ∼ 28
4.2 ∼ 18
1.4 ∼ 6.5
1.4 ∼ 6
9
10
11
45 ∼ 400
6 ∼ 24
3 ∼ 13
5 ∼ 24
Unit: kΩ
12
18 ∼ 80
4 ∼ 17
1.8 ∼ 8

Advertisement

Table of Contents

   Also See for Kawasaki EN500 Vulcan 500 LTD

This manual is also suitable for:

Vulcan 500 ltd

Comments to this Manuals

Symbols: 0
Latest comments:
  • Ricardo Paluan Apr 27, 2016 01:22:
    Adquiri recentemen​te uma moto vulcan 500 ano 1995. Tenho o 37 anos e iniciante no mundo motociclis​ta. Entretanto​, em razão só tempo e idade da moto, não tenho o manual do proprietá​rio, sendo este indispens