Table 7-15. Battery Charging Rates/Times (Approximate)
State of Charge
Battery
Voltage Read-
Amp-Hour
ing
12.7 V
12.6 V
12.3 V
12
12.0 V
11.8 V
The figures listed above assume that the battery is charging at room temperature. If warmer than room temperature, use a slightly shorter
charging time. If colder, use a slightly longer charging time.
The use of constant current chargers to charge sealed maintenance-free batteries is not recommended. Any overcharge will cause dry-
out and premature battery failure. If a constant current charger is the only type available, do not exceed the charge times listed above and
do not continue charging the battery if it gets hot. When charging, never exceed 15 volts for more than 30 minutes.
3
% of Charge
Amp Charger
100%
-
75%
1 hour,
10 minutes
50%
2 hours,
20 minutes
25%
3 hours,
20 minutes
0%
4 hours,
30 minutes
6
10
Amp Charger
Amp Charger
-
-
34 minutes
20 minutes
1 hour,
40 minutes
10 minutes
1 hour,
1 hour
40 minutes
2 hours,
1 hour,
14 minutes
20 minutes
2006 Buell Ulysses: Electrical
20
Amp Charger
-
10 minutes
20 minutes
30 minutes
40 minutes
7-41