Buell Ulysses 2006 Service Manual page 14

2006 buell ulysses
Table of Contents

Advertisement

HOME
d0243x8x
1.
Open secondary lock.
2.
Insert pick into cavity on inboard side
of connector.
3.
Pivot end of pick to release tang.
4.
Gently tug on wire to remove terminal
from housing.
NOTES
See
Figure B-3.
The tang in the chamber engages the
slot to lock the terminal in position.
On the pin side of the connector, tangs are positioned at
the bottom of each chamber, so the slot in the pin termi-
nal (on the side opposite the crimp tails) must face down-
ward.
On the socket side, tangs are at the top of each chamber,
so the socket terminal slot (on the same side as the
crimp tails) must face upward.
Up and down can be determined by the position of the
release button (used to separate the pin and socket
halves). Consider the button to always be on top of the
connector.
2.
Gently tug on wire end to verify that the terminal is
locked in place and will not back out of chamber.
3.
Rotate the hinged secondary lock inward until tabs fully
engage latches on both sides of connector.
4.
Insert the socket housing (plug) into the pin housing
(receptacle) until it snaps in place.
5.
Install connector on retaining device, either attachment
or rosebud clip.
B-2
2006 Buell Ulysses: Appendix B
Socket terminal
1
Pin terminal
4
1
Figure B-2. Release Tang and Back Out Terminals
Secondary lock open
4
Secondary lock open
Pin housing
2
3
Pin housing
Tang
d0244x8x
Figure B-3. Multilock Connector Cutaway View
Socket housing
2
Pick tool
3
Pick tool
Socket housing
Button
Tang

Advertisement

Table of Contents
loading