Frigidaire Dryer Servicing page 86

Affinity & gallery series 5.8 cu. ft. gas & electric dryers
Hide thumbs Also See for Dryer:
Table of Contents

Advertisement

Section 5 Troubleshooting
Electrical Tests For Gas Dryers
Thermal Limiter Trip Time
Run the following test at room temperature. Set the Time Dry cycle for 30 minutes and the heat selection at
maximum setting. Place a 100% exhaust block on the exhaust pipe. The dryer door should be open for this test and
the door switch held closed. The thermal limiter should trip and shut the dryer off after 1 to 5 minutes of operation.
To enable this test, the High Limit Thermostat must be bypassed and NTC2 should be removed from the heat duct.
NOTE
This test renders the thermal limiter inoperative, a new thermal limiter must be installed after this test.
Drum Temperatures
The following tests should be run with an unrestricted exhaust. The location of the thermal couple is to be the square
in the lint grill which is 12 squares left from the right edge of the lint blade and (2) squares forward. The tip should
extend 1.25" into the air grill. Set the dryer timer as needed for each test. The recordable temperature is to be the
maximum temperature following the heater off of the 3rd cycle.
No load is to be used for the following heat settings:
Heat Setting
Thermistor Status
Max*
Satisfied/Heater Off
Medium*
Satisfied/Heater Off
Low*
Satisfied/Heater Off
* Each opening temperature should be equal to or higher than the opening temperature for the next lower
temperature
setting.
5-6
Temperature (°F)
120 to 180
105 to 145
95 to 130