The fuser lamp FRU is color coded. The left and right fuser lamp
bracket access holes let you view the end of the lamp. Use the
following table to identify and install the correct lamp.
Description
Fuser Lamp 115V 875W
Fuser Lamp 220V 875W

Fuser Lower Exit Guide Assembly

1. Remove the fuser assembly.
2. Remove the fuser cover assembly.
3. Remove the fuser detack housing assembly.
4. Disconnect the sensors from the cable connectors.
5. Gently apply outward pressure on the left and right fuser side
frames to release the lower exit guide assembly.
4-36