Wire laid on the ground
1-Place the wire clockwise along
the whole path and fix it with
the appropriate nails supplied
(distance between the nails
1÷2 m).
– When positioning the perimter
wire, respect the rotation di-
rection around the bays (anti-
clockwise).
– In the straight stretches, fix the
wire so that it is not excessively
tight, wavy and/or twisted.
GB
– In the not straight stretches, fix
the wire so that it does not
twist, but so that it takes on a
regular bending.
Underground laid wire
1-Dig up the ground evenly and sym-
metrically compared to the traced
line highlighted on the ground.
2-Place the wire clockwise along the
whole path at the depth of some cen-
timetres (about 2÷3 cm) so not to
reduce the quality and the intensity of
the signal captured by the robot.
Important
In the path stretches, where it is
necessary to pass two parallel
wires (for example: connection
between the outside perimeter
and the inside marked areas),
they must be at a distance,
which must not exceed 1 cm.
wire fixing nails
wire fixing nails
3-When laying the wire, if necessary,
block it in some points with the appro-
priate nails to keep it in position dur-
ing the ground covering stage.
4-Cover up the whole wire with the soil
and make sure that it does not twist,
but that it remains straight and that,
in the curving stretches, it takes on
an even bending.
MAIN AREA
- 18 -
perimeter wire
perimeter wire
IDM - 41501600900.tif
passage aisle (<
70cm)
Closed
area
IDM - 41501701300.tif