4. Manual Adjustment
Manual Adjustment
1. TRK. Offset
2. Focus Gain
3. TRK. Gain
4. Focus Offset
5. Focus Balance
6. L.F. Offset
7. EQ BOOST
8. GD ADJ
Adjustment : Up/Down
SA.------ SI.-- EMG. 00
DVD SL 12 cm
On this screen, each item can be adjusted manually. Select the
[1]
[8]
desired number
to
from the remote commander, and cur-
rent setting for the selected item will be displayed, then increase
or decrease numeric value with ↑ key or ↓ key. This value is
stored in the EEPROM. If CLV has been applied, the jitter is dis-
played for reference for the adjustment.
[1]
TRK. Offset
Adjusts tracking offset.
[2]
Focus Gain
Adjusts focus gain.
[3]
TRK. Gain
Adjusts track gain.
[4]
Focus Offset
Adjusts focus offset.
[5]
Focus Balance
Adjusts focus balance.
[6]
L.F. Offset
Adjusts loop filter offset.
[7]
EQ BOOST
[8]
GD ADJ
5. Auto Adjustment
Auto Adjustment
1. Auto TRK. Offset
2. Auto Focus Balance
3. Auto Focus Offset
4. Auto Focus Gain
5. Auto TRK. Gain
6. Auto EQ
7. Auto L.F. Offset
8. Auto Group Delay
SA.------ SI.-- EMG. 00
DVD SL 12 cm
On this screen, each item can be adjusted automatically. Select the
[1]
[8]
desired number
to
from the remote commander, and se-
lected item is adjusted automatically.
[1]
Auto TRK. Offset
Adjusts tracking offset.
[2]
Auto Focus Balance Adjusts focus balance.
[3]
Auto Focus Offset
Adjusts focus offset.
[4]
Auto Focus Gain
Adjusts focus gain.
[5]
Auto TRK. Gain
Adjusts track gain.
Jitter 1D
[6]
Auto EQ
[7]
Auto L.F. Offset
[8]
Auto Group Delay
6. Memory Check
EEPROM DATA 1
CD LCD
Focus Gain
xx xx
TRK. Gain
xx xx
FCS Balance
xx xx
Focus Bias
xx xx
TRV. Offset
xx xx
L.F. Offset
xx xx
EQ Boost
xx xx
Mirror Time
xx --
_
DOWN : Next Data
CLEAR: Default Set
EEPROM DATA 2
CD LCD
RF Jitter
xx --
RF Level
xx --
FE Level
xx --
FE Balance
xx --
TRV. Level
xx --
Analog FRSW
xx xx
PLL Dac Gain xx xx
_
UP : Prev Data
CLEAR: Default Set
On this screen, current servo adjusted data stored in the EEPROM
are displayed. The adjusted data are initialized by pressing the
[CLEAR]
key, but be careful that they are not recoverable after
initialization.
Before clearing the adjusted data, make a note of the set data. This
screen will also appear if
Adjustment. In this case, default setting cannot be made.
For reference, the drive has been designed so that the gain center
value is 20 and offset value is 80. Other values will be in a range
of 10 to 80. If extreme value such as 00 or FF is set, adjustment
will be faulty. In such a case, check for disc scratch or cable dis-
connection, then perform adjustment again.
7. 5CHG Mecha Control
## 5CHG MechaControl Menu ##
ENTER
: Mecha Initial
OP/CL
: Tray Open/Close
UPDOWN : TurnTable Stop
RIGHT
: TurnTable RightTurn
LEFT
: Turntable LeftTurn
RETURN : Exit
[ENTER]
Mecha Initial
6-9
Adjusts loop filter offset.
-– DL -–
SL
L0
L1
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
page. 1/2
-– DL -–
SL
L0
L1
xx
xx
xx
xx
--
--
xx
--
--
xx
--
--
xx
--
--
xx
xx
xx
xx
xx
xx
page. 2/2
[0]
All is selected in the Drive Auto
Initializes the mechanism.
When the Drive Manual Operation
started, the mechanism is initialized.
Use this when an error occurred.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents