<WSW55>
Selector No.
1
Interval of time required for
the developing bias voltage
I
correction (hour)
8
(Not used.)
The setting example of the selector number is as follows;
No.1 2 3 4 5 6 7 8
0 0 0 0 0 0 0 0 : The developing bias voltage correction is performed on each print
0 0 0 1 1 0 0 0 : The developing bias voltage correction is performed when a print
0 0 0 1 0 0 1 0 : The developing bias voltage correction is performed when a print
1 1 1 1 1 1 1 1 : The developing bias voltage correction is not performed.
Function
255 (0xFF):
job.
job occurs after 24 hours (default value) or later.
job occurs after 72 hours or later.
App. 1-62
Setting and Specifications
0:
The developing bias voltage
correction is performed on each
print job.
1-72:
The developing bias voltage
correction is performed when a
print job occurs at specified
time or later.
73-254:
Not allowed to set.
The developing bias voltage
correction is not performed.