SiBE26-701
Check No. 6
Check for Thermistors
Disconnect the thermistor connector from PC board, then measure the resistance by using a
tester.
Thermistor temperature and resistance measurement
Temperature
Temperature
Discharge Pipe
(°C)
(kΩ)
-6.0
1120.0
-4.0
1002.5
-2.0
898.6
0.0
806.5
2.0
724.8
4.0
652.2
6.0
587.6
8.0
530.1
10.0
478.8
12.0
432.9
14.0
392.0
16.0
355.3
18.0
322.4
20.0
292.9
22.0
266.3
24.0
242.5
26.0
221.0
28.0
201.6
30.0
184.1
32.0
168.3
34.0
154.0
36.0
141.0
38.0
129.3
Troubleshooting
A
°C
-6.0
90.8
-4.0
81.7
-2.0
73.5
0.0
66.3
2.0
59.8
4.0
54.1
6.0
48.9
8.0
44.3
10.0
40.2
12.0
36.5
14.0
33.2
16.0
30.2
18.0
27.5
20.0
25.1
22.0
23.0
24.0
21.0
26.0
19.2
Temperature
Discharge Pipe
(°C)
Sensor (kΩ)
40.0
118.7
42.0
109.0
44.0
100.2
46.0
92.2
48.0
84.9
50.0
78.3
52.0
72.2
54.0
66.7
56.0
61.6
58.0
57.0
60.0
52.8
62.0
48.9
64.0
45.3
66.0
42.0
68.0
39.0
70.0
36.3
72.0
33.7
74.0
31.4
76.0
29.2
78.0
27.2
80.0
25.4
82.0
23.7
92.0
16.9
Temperature
B
°C
88.0
28.0
79.1
30.0
71.1
32.0
64.1
34.0
57.8
36.0
52.3
38.0
47.3
40.0
42.9
42.0
38.9
44.0
35.3
46.0
32.1
48.0
29.2
50.0
26.6
52.0
24.3
54.0
22.2
56.0
20.3
58.0
18.5
Application
Temperature
Discharge Pipe
(°C)
Sensor (kΩ)
94.0
15.8
96.0
14.8
98.0
13.9
100.0
13.1
102.0
12.3
104.0
11.5
106.0
10.8
108.0
10.2
110.0
9.6
112.0
9.0
114.0
8.5
116.0
8.0
118.0
7.6
120.0
7.1
122.0
6.7
124.0
6.4
126.0
6.0
128.0
5.7
130.0
5.4
132.0
5.4
134.0
4.8
136.0
4.6
138.0
4.3
Diagnosis by Remote Controller
Unit : kΩ
A
B
17.6
17.0
16.2
15.6
14.8
4.2
13.6
13.1
12.5
12.0
11.5
11.1
10.6
10.3
9.8
9.5
9.1
8.8
8.4
8.2
7.8
7.6
7.2
7.0
6.9
6.7
6.2
6.0
5.7
5.5
5.3
5.2
Heat
Radiator fin
exchanger
(Indoor/
Outdoor
units)
Suction air
Remote
controller
Air
Outdoor air
Suction pipe
Temperature
Discharge Pipe
(°C)
Sensor (kΩ)
140.0
4.1
142.0
3.9
144.0
3.7
146.0
3.5
148.0
3.3
150.0
3.2
152.0
3.0
154.0
2.9
156.0
2.7
158.0
2.6
160.0
2.5
162.0
2.3
164.0
2.5
166.0
2.1
168.0
2.0
170.0
1.9
172.0
1.9
174.0
1.8
176.0
1.7
178.0
1.6
180.0
1.5
177