12.4. How to Replace the LLP (Leadless Leadframe Package) IC

12.4.1. Preparation
• PbF (: Pb free) Solder
• Soldering Iron
Tip Temperature of 700°F ± 20°F (370°C ± 10°C)
Note:
We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with less
experience could overheat and damage the PCB foil.
• Hot Air Desoldering Tool
Temperature: 608°F ± 68°F (320°C ± 20°C)
12.4.2. Caution
• To replace the IC efficiently, choose the right sized nozzle of the hot air desoldering tool that matches the IC package.
• Be careful about the temperature of the hot air desoldering tool not to damage the PCB and/or IC.
12.4.3. How to Remove the Shield Case
Note:
If you don't have special tools (ex. Hot air disordering tool), conduct the following operations.
1. Cut the case along perforation.
2. Remove the cut part.
3. Cut the four corners along perforation.
4. Remove the reminds by melting solder.
12.4.4. How to Install the Shield Case
Note:
• If you don't have special tools (ex. Hot air disordering tool), conduct the following operations.
• Shield case's No. : PNMC1013Z