Disassembly Procedures
!
WARNING
Top Cover Removal
1. Disconnect power supply to unit.
2. Remove 2 10mm screws from washer back.
3. Slide Top Cover towards the rear to clear the screw
head from flange on the bottom side of the Top Cover.
Water Level Sensor Removal
1. Disconnect power supply to unit.
2. Remove Top Cover.
24
To avoid risk of electrical shock, personal injury or death;
disconnect power to unit before servicing.
3. Remove harness plug.
4. Remove Pressure Hose.
5. Remove single attachment screw.
16026186
©2006 Maytag Services