3.2.12 Multiple copies

(1) Copying the parameter settings
Parameter settings of an inverter can be read. The settings of maximum three inverters can be stored in
the FR-PU07. You can also copy the stored parameter settings to another inverter of the same series.
Confirm for setting
· Is the PU operation mode selected? → If not, press
· Is the inverter stopped? → If it is running, press
· Is the Pr. 77 setting of the copy destination inverter correct? → Set "0 or 2" in Pr. 77.
· Is the inverter of the copy destination the same series as that of the copy source? → Select the inverter of the same series.
FR-A720-0.4K → FR-A720-0.75K
Example:
× FR-A720-0.4K → FR-F720-0.75K
CAUTION
Turning power OFF during parameter copy (read, write) as below, processing is not completely ended.
Perform parameter copy again.
· Turn OFF the inverter power.
· The FR-PU07BB (battery mode) power is OFF or battery exhaustion.
· Remove the FR-PU07 from the inverter.
· Pull out the PU cable.
76
to select the PU operation mode.
to stop it.
Parameters can be copied only to the
same series inverters.