Electrical Diagram - Bosch C 1210 ES Installation Manual

Bosch indoor residential and commercial models tankless water heaters temperature modulated with electronic ignition suitable for heating potable water and space heating, natural & liquefied petroleum (lp) gas
Table of Contents

Advertisement

Electrical diagram

9
Electrical diagram
16
20
19
18
17
21
Fig. 72 Electrical scheme
1
Inlet water temperature sensor
2
Outlet water temperature sensor
3
Backflow temperature sensor
4
Cascading output connection
5
Cascading input connection
6
Ionization sensor
7
Water flow sensor
8
Flue gas limiter
9
Heat exchanger overheat sensor (ECO)
10
Gas valve
11
Exhaust temperature sensor
12
Water valve
13
Primary fan
14
ON/OFF switch
15
Secondary fan
16
Power supply cord
17
Power connection
18
Ignition electrodes
19
Ground post
20
Antifreeze kit connection
21
Fuse
22
Fuse
54
15
13
M
M
22
12
M
E
PS
T=104°C
T=220°F
16
...
1
20
...
14
JP2
JP7
JP5
6720608158-01.1AL
T=90°C
T=194°F
11
10
9
T=110°C
T=230°F
8
7
FS
6
Casc.
input
Casc.
output
Back flow
1
JP8
JP6
5
4
3
2
1
6 720 644 887