PARAMETER TABLE
A2
TERMINATOR
To signalthe end of a command, it is necessaryto use a
semicolon (;). The digit where this special character
must appear differs dependingon commands.
TYPES OFCOMMANDS
Commands can be classified as shown below:
-{
Set Command
(Sets a
Input
particular
Command
condition.)
(Input
to the
Read Command
radiotelephone)
(Reads an answer.)
Commands
Answer Command
(Transmits a
condition.)
Output
Command
(From the
radiotelephone)
For example, note the following in the case of the MD
command (Operatingmode):
.
To set the modeto USB, the following command is
sent from the computer to the radiotelephone:
uMD2;"
(Set Command)
.
To read the mode, the following command is sent
from the computer to the radiotelephone:
uMD;"
(Read Command)
.
When the Read Command above has been sent, the
followi(lgcommand is returnedto the computer:
uMD2;"
(Answer Command)
For-
No. of
mat
Name
Digits
Format
No.
1
SW
1
0: OFF
1: ON
2
MODE
1
1: LSB
5: AM
2: USB
6: DATA
3:CW
4
FREQUENCY
11
Represented in Hz.
Ex.: 00008192000 is
8.192 MHz
5
CLARIFIER
5
The first digit is u+"or
FREQUENCY
u_",and the remaining
four digits indicate the
frequency in Hz.
Ex.: +1000 is +1.00 kHz
u_"canbe used for U+".
7
MEMORY
2
Represented using
CHANNEL
01-80.
9
MEMORY
1
0: Receive
CHANNEL
1: Transmit
SPLIT DATA
10
MEMORY
1
0: Not locked out
LOCKOUT
1: Locked out
11
TX/RX
1
0: Receive
1: Transmit
22 METER VALUE
4
Represented using
0000
(min.)-0015
(max.). Relative
values are output.
25
PITCH
2
00: 400 Hz
01: 800 Hz
30
ANTENNA
1
0: Antenna tuner thru
TUNER
1: Antenna tuner in-line
31
GAIN
3
AF
gain:
Represented using
000 (min.)-255 (max.).
MIC
gain:
000: Low gain
001:
High gain
46
LEVEL
3
Represented using
000 (min.)-255 (max.).
47
POWER
3
015: Low power
CONTROL
025: Medium power
050: High power
100: Maximum power
49
SEMI BREAK-
4
Represented in msec
IN DELAY
using 0000-1800
TIME
(200 Hz steps).
51
4
Represented in msec
VOX DELAY
using 0200-2000
TIME
(200
Hz steps).