Page 2
KX-TG4753B/KX-TG470B/KX-TGA405B WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians.
KX-TG4753B/KX-TG470B/KX-TGA405B 1 Safety Precautions 1.1. For Service Technicians • Repair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires, injury or electric shock, which can be caused by improper repair work.
KX-TG4753B/KX-TG470B/KX-TGA405B 2.2.1. Suggested PbF Solder There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper (Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu), or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the manufacturer's specific instructions for the melting points of their products and any precautions for using their product with other materials.
KX-TG4753B/KX-TG470B/KX-TGA405B 4 Technical Descriptions 4.1. US-DECT Description The frequency range of 1.92 GHz-1.93 GHz is used. Transmitting and receiving carrier between base unit and handset is same frequency. Refer to Frequency Table (P.66). 4.1.1. TDD Frame Format 5 ms 5 ms Up Link ( Handset - >...
Page 8
KX-TG4753B/KX-TG470B/KX-TGA405B 4.1.3. Signal Flowchart in the Radio Parts Reception Base unit: A voice signal from TEL line is encoded to digital data and converted into a 1.9GHz modulated radio signal by BBIC(IC501). The RF signal, after which is amplified in BBIC, is fed to selected antenna.
KX-TG4753B/KX-TG470B/KX-TGA405B 4.4. Circuit Operation (Base Unit) General Description: (BBIC, Flash Memory, EERROM) is a digital speech/signal processing system that implements all the functions of speech compression, record and playback, and memory management required in a digital telephone answering machine. The BBIC system is fully controlled by a host processor. The host processor provides activation and control of all that functions as follows.
Page 12
KX-TG4753B/KX-TG470B/KX-TGA405B 4.4.4. Power Supply Circuit/Reset Circuit The power supply voltage from AC adaptor is converted to VBAT (3.0V) in IC302. And +3.0V for peripherals and analog part is insulated from VBAT by Doubler of BBIC. Circuit Operation: +3.0V VBAT IC601...
KX-TG4753B/KX-TG470B/KX-TGA405B 4.4.4.1. Charge Circuit The voltage from the AC adaptor is supplied to the charge circuits. +5.5V F301 CHARGE+ CHARGE-...
Page 14
KX-TG4753B/KX-TG470B/KX-TGA405B 4.4.5. Telephone Line Interface Telephone Line Interface Circuit: Function • Bell signal detection • ON/OFF hook and pulse dial circuit • Side tone circuit Bell signal detection and OFF HOOK circuit: In the idle mode, Q141 is open to cut the DC loop current and decrease the ring load. When ring voltage appears at the Tip (T) and Ring (R) leads (When the telephone rings), the AC ring voltage is transferred as follows: T →...
Page 15
KX-TG4753B/KX-TG470B/KX-TGA405B 4.4.6. Parallel Connection Detect Circuit/Auto Disconnect Circuit Function: In order to disable call waiting and stutter tone functions when using telephones connected in parallel, it is necessary to have a circuit that judges whether a telephone connected in parallel is in use or not. This circuit determines whether the telephone connected in parallel is on hook or off hook by detecting changes in the T/R voltage.
Page 16
KX-TG4753B/KX-TG470B/KX-TGA405B 4.4.7. Calling Line Identification (Caller ID)/Call Waiting Caller ID Function: Caller ID The caller ID is a chargeable ID which the user of a telephone circuit obtains by entering a contract with the telephone company to utilize a caller ID service. For this reason, the operation of this circuit assumes that a caller ID service contract has been entered for the circuit being used.
Page 17
KX-TG4753B/KX-TG470B/KX-TGA405B Call Waiting Caller ID Calling Identity Delivery on Call Waiting (CIDCW) is a CLASS service that allows a customer, while off-hook on an existing call, to receive information about a calling party on a waited call. The transmission of the calling information takes place almost immediately after the customer is alerted to the new call so he/she can use this information to decide whether to take the new call.
KX-TG4753B/KX-TG470B/KX-TGA405B 4.7. Circuit Operation (Handset) 4.7.1. Outline Handset consists of the following ICs as shown in Block Diagram (Handset) (P.18). • DECT BBIC (Base Band IC): IC1 - All data signals (forming/analyzing ACK or CMD signal) - All interfaces (ex: Key, Detector Circuit, Charge, EEPROM, LCD) •...
KX-TG4753B/KX-TG470B/KX-TGA405B 4.7.3. Charge Circuit Circuit Operation: When charging the handset on the Base Unit, the charge current is as follows; DC+(6.5 V) → F301 → R371 → R372 →CHARGE+(Base) → CHARGE+(Handset) → Q4 → D7→ F1 → BATTERY+... Battery... BATTERY- → R45 → GND → CHARGE-(Handset)→ CHARGE-(Base) → GND → DC-(GND) In this way, the BBIC on Handset detects the fact that the battery is charged.
KX-TG4753B/KX-TG470B/KX-TGA405B 4.11. Circuit Operation (Range Extender) (BBIC, EEPROM) is a digital speech/signal processing system. The BBIC system is fully controlled by a host processor. The host processor provides activation and control of all that functions as follows. TDD & TDMA...
KX-TG4753B/KX-TG470B/KX-TGA405B 4.11.3. Power Supply Circuit The power supply voltage from AC adaptor is converted to VBAT (3.0 V) in IC302. VBAT is used for BBIC and all peripherals. Circuit Operation: VBAT IC501 IC302 VBAT 6.5V pin 10 3.0V AC Adaptor...
KX-TG4753B/KX-TG470B/KX-TGA405B 5 Location of Controls and Components Refer to the Operating Instructions. Note: You can download and refer to the Operating Instructions (Instruction book) on TSN Server. 6 Installation Instructions Refer to the Operating Instructions. Note: You can download and refer to the Operating Instructions (Instruction book) on TSN Server.
KX-TG4753B/KX-TG470B/KX-TGA405B 8 Test Mode 8.1. Engineering Mode 8.1.1. Base Unit Important: Make sure the address on LCD is correct when entering new data. Otherwise, you may ruin the unit. Soft keys {FLASH} {FLASH} {CALL WAIT} {CALL WAIT} Naviga tor key/...
Page 29
KX-TG4753B/KX-TG470B/KX-TGA405B Frequently Used Items (Base Unit) ex.) Items Address Default Data New Data Remarks Frequency 00 07 / 00 08 00/01 Use these items in a READ-ONLY mode to confirm the contents. Careless rewriting may 00 02 ~ 00 06 Given value cause serious damage to the computer system.
Page 30
KX-TG4753B/KX-TG470B/KX-TGA405B 8.1.2. Handset Important: Make sure the address on LCD is correct when entering new data. Otherwise, you may ruin the unit. Soft keys {FLASH} {FLASH} {CALL WAIT} {CALL WAIT} Naviga tor key/ (Volume) key {OFF} {OFF} Dial keypad Dial keypad...
Page 31
KX-TG4753B/KX-TG470B/KX-TGA405B Frequently Used Items (Handset) ex.) Items Address Default Data New Data Possible Adjusted Possible Adjusted Remarks Value MAX (hex) Value MIN (hex) Battery Low 00 12/00 13 00 / 00 (*2) Frequency 00 07 / 00 08 00 / 01...
KX-TG4753B/KX-TG470B/KX-TGA405B 9 Service Mode 9.1. How to Clear User Setting (Handset Only) Handset Press simultaneously until a beep sound is heard. Then single handset is initialized. (The contents of user setting are reset to factory default) *Usage time is not cleared.
KX-TG4753B/KX-TG470B/KX-TGA405B 10 Troubleshooting Guide 10.1. Troubleshooting Flowchart 10.1.1. Flow Chart (without Range Extender) FLOW CHART Not working Power ON Base Unit Check Power Not playback Playback Pre-Message Check Playback Not record (*1) Record Check Record Link No link No charge...
KX-TG4753B/KX-TG470B/KX-TGA405B 10.1.2. Flow Chart (Range Extender) Not working Power ON Range Extender Check Power Power ON with pressing "1", "6" and "#" of Handset Not Link Link Check Link Range Check the RF part Cross Reference: Check Link (P.41) Check Power (P.34) Check the RF part (P.42)
KX-TG4753B/KX-TG470B/KX-TGA405B 10.1.3.2. Handset Is the battery inserted to BATT+ and BATT-? Check the battery and around BATT+ and Is the voltage of TP-VBAT 2.3 V more? BATT- are not shorted. Is the voltage of TP 3.0 V about 3.0 V? Check Power Supply Circuit/Reset Circuit.
Page 36
KX-TG4753B/KX-TG470B/KX-TGA405B <How to change the Auto Disconnect activation time and VOX level> A) Auto Disconnect activation time: Some Telephone Company lines (fiber or cable) ON Hook and OFF Hook voltages are lower than conventional lines, which may cause a malfunction of Auto Disconnect detection. To solve this problem, try changing the Auto Disconnect activation through the procedures below.
Page 37
KX-TG4753B/KX-TG470B/KX-TGA405B B) Vox level: It makes easier to detect a small voice (caller) by raising the sensitivity of VOX level. Therefore, the recording of TAM is not turned off during a detection. 1) ~ 2) are same as (A). 3) Press "5","1","1".
KX-TG4753B/KX-TG470B/KX-TGA405B 10.1.5. Check Playback 10.1.5.1. Base Unit Check VDDC (1.2 V): Test Point [VDDC] Check Power Supply Circuit. Check output of BBIC (Pin 29, 31). Check BBIC and Flash Memory. Check Speaker and its surroundings. Cross Reference: Note: Power Supply Circuit/Reset Circuit (P.12) Flash Memory is IC601.
KX-TG4753B/KX-TG470B/KX-TGA405B 10.1.7. Check Link 10.1.7.1. Base Unit Does Base Unit make link with normal working Base Unit is OK. Check Handset. Handset? Is the voltage of VBAT about 3.0 V? Check around Power Supply Circuit. Is the voltage of VDDC about 1.2 V? Adjust +3.0V voltage to 3.0 V.
Page 40
KX-TG4753B/KX-TG470B/KX-TGA405B 10.1.7.2. Handset Does Handset make link with Base Unit? Handset is OK. Check Base Unit. (Correct working unit) Is the voltage of TP VBAT about 2.2~2.8 V? Check the batteries. Check around Power Supply Circuit/Reset Circuit. Is the voltage of TP VDDC about 1.2 V? Is the voltage of TP 3.0 V about 3.0 V?
Page 41
KX-TG4753B/KX-TG470B/KX-TGA405B 10.1.7.3. Range Extender Does Range Extender make link with normal working Range Extender in OK. Check Base Unit and Base Unit and Handset? Handset. Is the voltage of VBAT about 3.0 V? Check around Power Supply Circuit. Is the voltage of VDDC about 1.2 V? Adjust +3.0V voltage to 3.0 V.
KX-TG4753B/KX-TG470B/KX-TGA405B 10.1.8. Check the RF part 10.1.8.1. Finding out the Defective part Prepare Regular HS (*1) and Regular BU (*2) and Regular RE (*3). Handset is Power ON with “1“, “6“and “#“. START HS is defective Use Regular HS BU is defective...
Page 43
KX-TG4753B/KX-TG470B/KX-TGA405B 10.1.8.2. RF Check Flowchart Each item (1 ~ 5) of RF Check Flowchart corresponds to Check Table for RF part (P.44). Please refer to the each item. Start Link Control Check BBIC interface parts. confirmation signal (RF Block <->BBIC on BU/HS P.C.B)
Page 44
KX-TG4753B/KX-TG470B/KX-TGA405B 10.1.8.3. Check Table for RF part Item BU (Base Unit) Check HS (Handset) Check Link Confirmation Normal 1. Register Regular HS to BU (to be 1. Register HS (to be checked) to Regular checked). HS, BU Mode [Normal Mode] 2.
Page 45
KX-TG4753B/KX-TG470B/KX-TGA405B 10.1.8.5. TEST RANGE Check Circuit block which range is defective can be found by the following check. Item BU (Base Unit) Check HS (Handset) Check Range Confirmation TX TEST 1. Register Regular HS to BU (to be checked). 1. Register HS (to be checked) to Regular BU.
KX-TG4753B/KX-TG470B/KX-TGA405B 10.1.9. Registering a Handset to the Base Unit The supplied handset and base unit are pre-registered. If for some reason the handset is not registered to the base unit, re-register the handset. 1 Handset: {MENU} i # 1 3 0...
KX-TG4753B/KX-TG470B/KX-TGA405B 10.1.12. Check Handset Transmission Check MIC of handset. Check handset Tx in Signal Route. Cross Reference: Signal Route (P.25) 10.1.13. Check Handset Reception Check speaker of handset. Check handset Rx in Signal Route. Cross Reference: Signal Route (P.25) Note: When checking the RF part, Refer to Check the RF part (P.42).
KX-TG4753B/KX-TG470B/KX-TGA405B 11 Disassembly and Assembly Instructions 11.1. Disassembly Instructions 11.1.1. Base Unit Remove the 4 screws to remove the cabinet cover. Remove the solders. Cabinet cover Solders Remove the screw and pararell wire to remove the main P.C. board.
Page 49
KX-TG4753B/KX-TG470B/KX-TGA405B Remove the 2 screws to remove the Jack holder. Remove the 2 screws to remove the operational P.C.B board.
Page 50
KX-TG4753B/KX-TG470B/KX-TGA405B 11.1.2. Handset 2 screws Remove the 2 screws. Insert a plastic card. (Ex. Used SIM card etc.) Cabinet body between the cabinet body and the cabinet cover, then pull it along the gap to open the cabinet. Cabinet cover Likewise, open the other side of the cabinet.
KX-TG4753B/KX-TG470B/KX-TGA405B 11.2. How to Replace the Base Unit LCD Fit the heatseal of a new LCD. Vertical Interval Tolerance 0.2mm New LCD Horizontal Interval Tolerance 0.2mm If interval tolerance between center lines is less than 0.2 mm, it is o.k.
Page 54
KX-TG4753B/KX-TG470B/KX-TGA405B Attach the LCD and fix by hook A (two points).
KX-TG4753B/KX-TG470B/KX-TGA405B 11.3. How to Replace the Handset LCD Note: The illustrations are simplified in this page. They may differ from the actual product. P. C. board Vertical Interval Tolerance Peel off the FFC (Flexible Flat Cable) from 0.2 mm the LCD, in the direction of the arrow. Take care to ensure that the foil on the P.C.
KX-TG4753B/KX-TG470B/KX-TGA405B 12 Measurements and Adjustments This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in Troubleshooting Guide (P.33) 12.1. Equipment Required • Digital multi-meter (DMM): it must be able to measure voltage and current.
Page 57
KX-TG4753B/KX-TG470B/KX-TGA405B 12.2.2. Connections (Handset) Connect the DC Power or Battery to BATT+ and BATT-. Connect the JIG cable GND (black) to GND. Connect the JIG cable UTX (yellow) to UTX and URX (red) to URX. URX (red) To Serial Port...
Page 58
KX-TG4753B/KX-TG470B/KX-TGA405B 12.2.4. How to install Batch file into P.C. Insert the Batch file CD-ROM into CD-ROM drive and copy PNZZTG**** folder to your PC (example: D drive). <Example for Windows> On your computer, click [Start], select Programs Open an MS-DOS mode window.
Page 59
KX-TG4753B/KX-TG470B/KX-TGA405B 12.2.5. Commands (Base Unit) See the table below for frequently used commands. Command name Function Example rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data from address “00 00” to “FF” is read out.
KX-TG4753B/KX-TG470B/KX-TGA405B 12.3. Adjustment Standard (Base Unit) When connecting the simulator equipment for checking, please refer to below. 12.3.1. Bottom View Note: (*1) is referred to No.2 of Check Check Table for RF part (P.44) (*2) is referred to Power Supply Circuit/Reset Circuit (P.12)
KX-TG4753B/KX-TG470B/KX-TGA405B 12.4. Adjustment Standard (Charger Unit) When connecting the simulator equipment for checking, please refer to below. 12.4.1. Bottom View Digital Volt Meter /2 W DC POWER DC 5.5 V...
KX-TG4753B/KX-TG470B/KX-TGA405B 12.5. Adjustment Standard (Range Extender) When connecting the simulator equipment for checking, please refer to below. 12.5.1. Bottom View Spectrum Analyzer Frequency Counter * Send command "SFR", then the frequency output on this TP. Oscilloscope (*1) * Start Monitor Note: (*1) is referred to Power Supply Circuit (P.24)
KX-TG4753B/KX-TG470B/KX-TGA405B 12.7. Things to Do after Replacing IC or X'tal If repairing or replacing EEPROM and X'tal, it is necessary to download the required data such as Programming data or adjustment data, etc in memory. The set doesn't operate if it is not executed.
Page 65
KX-TG4753B/KX-TG470B/KX-TGA405B 12.7.1.3. Handset First, operate the PC setting according to The Setting Method of JIG (P.56). Then download the appropriate data according to the following procedures. Items How to download/Required adjustment EEPROM (IC3) Adjusted parameter data is stored in memory.
KX-TG4753B/KX-TG470B/KX-TGA405B 13 Miscellaneous 13.1. How to Replace the LLP (Leadless Leadframe Package) IC Note: This description is only applied on the model with Shield case. 13.1.1. Preparation • PbF (: Pb free) Solder • Soldering Iron Tip Temperature of 700 °F ± 20 °F (370 °C ± 10 °C) Note: We recommend a 30 to 40 Watt soldering iron.
Page 68
KX-TG4753B/KX-TG470B/KX-TGA405B 13.1.4. How to Install the IC 1. Place the solder a little on the land where the radiation GND pad on IC bottom is to be attached. Soldering Iron Land Solder P.C.Board 2. Place the solder a little on the land where IC pins are to be attached, then place the IC.
KX-TG4753B/KX-TG470B/KX-TGA405B 13.2. How to Replace the Flat Package IC Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a soldering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins.
Page 70
KX-TG4753B/KX-TG470B/KX-TGA405B 13.2.3. How to Install the IC 1. Temporarily fix the FLAT PACKAGE IC, soldering the two marked pins. *Check the accuracy of the IC setting with the corresponding soldering foil. 2. Apply flux to all pins of the FLAT PACKAGE IC.
KX-TG4753B/KX-TG470B/KX-TGA405B 14 Schematic Diagram 14.1. For Schematic Diagram 14.1.1. Base Unit (Schematic Diagram (Base Unit_Main)) Notes: 1. DC voltage measurements are taken with voltmeter from the negative voltage line. Important Safety Notice: Components identified by mark have special characteristics important for safety.
KX-TG4753B/KX-TG470B/KX-TGA405B 16 Exploded View and Replacement Parts List 16.1. Cabinet and Electrical Parts (Base Unit) E1 (*1) PCB1 PCB2 Ref.No. Figure 2.6 x 8mm Note: (*1) This cable is fixed by welding. Refer to How to Replace the Base Unit LCD (P.53)
(*1) This cable is fixed by welding. Refer to How to Replace the Handset LCD (P.55). (*2) The rechargeable Ni-MH battery HHR-4DPA is available through sales route of Panasonic. (*3) Attach the SPACER (No. 121) to the exact location described above.
KX-TG4753B/KX-TG470B/KX-TGA405B 16.6. Replacement Parts List Safety Ref. Part No. Part Name & Description Remarks 1. RTL (Retention Time Limited) PQJJ1T039L JACK, MODULAR Note: K2ECYZ000001 JACK, DC The “RTL” marking indicates that its Retention Time is PNKF1228Z1 CABINET COVER PS-HB PNHA1013Z...
Page 102
KX-TG4753B/KX-TG470B/KX-TGA405B Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks R164 D0GB272JA057 2.7k C512 ECUE1A104KBQ 0.1 R165 ERJ3GEYJ273 C513 ECUV1A225KBV 2.2 R167 D0GG270JA007 27 C514 ECUE1A104KBQ 0.1 R171 D0GA220JA021 22 C515...
Page 103
KX-TG4753B/KX-TG470B/KX-TGA405B 16.6.2. Handset Safety Ref. Part No. Part Name & Description Remarks 16.6.2.1. Cabinet and Electrical Parts LED12 B3ACB0000190 LED (COILS) C812 PQLQR4C8N2J COIL G1CR18J00004 COIL Safety Ref. Part No. Part Name & Description Remarks (RESISTOR ARRAYS) D1H83314A013 RESISTOR ARRAY...
Page 104
KX-TG4753B/KX-TG470B/KX-TGA405B Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks ECUE1A104KBQ 0.1 E106 PQHG10729Z RUBBER PARTS, RECEIVER ECUE1A104KBQ 0.1 E107 PNVE1002Z BATTERY TERMINAL ABS-HB ECUE0J105KBQ 1 K2HD103D0001 JACK ECUV1A225KBV 2.2 K5H252Y00002 FUSE...
Page 105
(FUSE) (*1) You can download and refer to the Operating F301 K5H302Y00003 FUSE Instructions (Instruction book) on TSN Server. (RESISTOR ARRAYS) RA501 EXB28V330 RESISTOR ARRAY 16.6.5.1. KX-TG4753B RA502 EXB28V103 RESISTOR ARRAY RA504 D1H468020001 RESISTOR ARRAY (RESISTORS) Safety Ref. Part No.
Page 106
KX-TG4753B/KX-TG470B/KX-TGA405B Safety Ref. Part No. Part Name & Description Remarks PQZZ1CD300E JIG CABLE (*1) PNZZTG4741M BATCH FILE CD-ROM (*1) PQZZ430PIR TIP OF SOLDERING IRON (*2) PQZZ430PRB RUBBER OF SOLDERING IRON (*2) T.I/N KXTG4753B KXTGA470B KXTGA405B...
Page 107
KX-TGA470B KX-TGA405B Digital Cordless Answering System B: Black Version (for U.S.A.) Please file and use this supplement manual together with the service manual for Model No.KX-TG4753B/ KX-TGA470B/KX-TGA405B, Order No. KM41201527CE. TABLE OF CONTENTS PAGE 1 REPLACEMENT PARTS LIST--------------------------------- 2 1.1. REFERENCE CHART------------------------------------ 2 1.2.
Page 108
KX-TG4753B/KX-TGA470B/KX-TGA405B 1 REPLACEMENT PARTS LIST 1.1. REFERENCE CHART Reason for Change *The following items (1-8) indicate the reason for change. See the “Notes” column for each part in ORIGINAL AND NEW PARTS COMPARISON LISTS. 1. Improve performance Remarks: *c: To share the parts with other models 2.
Page 109
KX-TGA470B KX-TGA405B Digital Cordless Answering System B: Black Version (for U.S.A.) Please file and use this supplement manual together with the service manual for Model No.KX-TG4753B/ KX-TGA470B/KX-TGA405B, Order No. KM41201527CE. TABLE OF CONTENTS PAGE 1 REPLACEMENT PARTS LIST--------------------------------- 2 1.1. REFERENCE CHART------------------------------------ 2 1.2.
Page 110
KX-TG4753B/KX-TGA470B/KX-TGA405B 1 REPLACEMENT PARTS LIST 1.1. REFERENCE CHART Reason for Change *The following items (1-8) indicate the reason for change. See the “Notes” column for each part in ORIGINAL AND NEW PARTS COMPARISON LISTS. 1. Improve performance Remarks: *j : To meet the standards.
Page 111
KX-TGA470B KX-TGA405B Digital Cordless Answering System B: Black Version (for U.S.A.) Please file and use this supplement manual together with the service manual for Model No.KX-TG4753B/ KX-TGA470B/KX-TGA405B, Order No. KM41201527CE. TABLE OF CONTENTS PAGE 1 REPLACEMENT PARTS LIST--------------------------------- 2 1.1. REFERENCE CHART------------------------------------ 2 1.2.
Page 112
KX-TG4753B/KX-TGA470B/KX-TGA405B 1 REPLACEMENT PARTS LIST 1.1. REFERENCE CHART Reason for Change *The following items (1-8) indicate the reason for change. See the “Notes” column for each part in ORIGINAL AND NEW PARTS COMPARISON LISTS. 1. Improve performance Remarks: *m: Discontinued (To be replaced with a new part) 2.