Download  Print this page

Power Connection - Electrolux Wascator TT200 Operating And Installation Manual

Electrolux wascator gas tumble dryer
Hide thumbs

Advertisement

Table of Contents
Electrical installation
To be carried out by a skilled, competent person.
The tumble dryer requires its own fuse group.
For each tumbler, place a multi-pole fixed switch
Fig.
in the fixed installation. Place it in such a way
4
that it is easily accessible but will not be mistaken
for the tumbler main switch.
The motor has an inbuilt thermo-fuse, which is
why motor protection is not required in the
installation.
Remove the top cover from the tumbler in order
Fig.
to connect the cable. Set up the tumbler as a
5
fixed installation. See dimensions in the table
below.
Before remounting the top cover: Check the
direction of rotation. See function checks, page
16. If the drum rotates in the wrong direction,
switch 2 phases.
The tumble dryer must be provided with extra
protection in accordance with relevant
regulations.
5
Cable dimensioning table
Drum
volume
200/270 l
200-240V
200/270 l
400-440V 3N/3 50/60 Hz
200/270 l
200-230V
Machines marked 230V or 400V (new European voltage as per IEC 38)
can be connected to 220V or 380V mains plugs without any problems.
Installation GAS 200/270 litres
Voltage
Power
input
1N 50/60 Hz
1,0 kW
0,5 kW
3 50/60 Hz
0,5 kW
4
3~:
L
1
L
2
L
3
3N~:
L
1
L
2
L
3
N
1N~:
L
1
N
Heating
Connecting lead
Dimension
3 × 1,5 mm
Gas 12 kW
5/4 × 1,5 mm
Gas 12 kW
4 × 1,5 mm
Gas 12 kW
7
L 1
L 2
L 3
L 1
L 2
L 3
N
L 1
N
Fuse
2
10A
2
10A
2
10A

Hide quick links:

Advertisement

Table of Contents
loading

  Related Manuals for Electrolux Wascator TT200

This manual is also suitable for:

Wascator tt270