Evacuation system

Fresh air intake
In order for the machine to work optimally, with
Fig.
the shortest possible drying time, it is important
12
for the air intake to the room to come from the
open air and for the same amount of air as
enters the room to be evacuated. In order to
avoid draught in the room, it is best to place the
air intake behind the machine. See example
fig.12. The area of the air intake opening must be
5 times the area of the evacuation pipe. The
resistance in the damper / slatted shutter must
not exceed 10 Pa (0.1 mbar). The air
consumption is shown in the table. (Fig. 14).
Evacuation pipe / duct
It is recommended to connect each machine to a
separate, smooth-faced evacuation pipe with as
low air resistance as possible.
The pipe must lead to the outside and be
protected against rain and impurities. The length
of the evacuation pipe is given in metres. For
each 90° bend - add 2 metres.
For each 45° bend - add 1 metre.
Set the damper in accordance with the table,
Fig.
ensuring that the optimal efficiency is obtained.
13
Lengths and dimensions can be seen from the
Fig.
table.
14
If in doubt with regard to the design of an
evacuation system, please do not hesitate to
contact our service organisation / dealer.
14
Hz
Type
Heating
in litres
200
12 kW
50
270
12 kW
200
12 kW
60
270
12 kW
Installation GAS 200/270 litres
Air
Static
consumpt
pressure evacuation pipe match different pipe lengths
525 m
3
/h
150 Pa
525 m
3
/h
150 Pa
525 m
3
/h
250 Pa
525 m
3
/h
250 Pa
12
13
Diameter of
Setting of damper scale to
0-15 m
160 mm
2
200 mm
2
160 mm
1
200 mm
1
A
15-30 m
30-60 m 60-100 m
3
3-4
5
3
3-4
5
1-2
2-3
4-5
1-2
2-3
4-5
× A