REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION.
RM 3662, RM 3663 RM 3862, RM 3863
Automatic-Manual Energy Selector
FOR YOUR SAFETY
If you smell gas:
1. Open windows,
2. Don' t touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasollne or other
flammable vapors and liquids In the
vicinity of this or any other appliance.
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or
property damage. Refer to thfs
manual. For assistance or additional,
Information consult a qualified
installer, service agency or the gas
supplier.
USA
Service office
The Dometic Corporation
509 South Poplar Street
LaGrange, IN 46761
Phone: 219-463-4858
822 70 13-03
Corporate Office
2320 Industrial Parkway Elkhart, IN 46515
For Service Center Assistance
Call: 800-544-4881
Contents:
Installation
O p e r a t i n g lnstructions 8
Maintenance & Service
AVIS
Cet appareil doit etre ropare
seulement par un reparateur
I' appareil pourralt etre
extremement dangeruse, et
pourralt causer mal ou mort.
CANADA
Dometic Distribution Inc.
866 Langs Drive
Cambridge,Ontario
N3H 2N7 Canada
Phone: 519-653-4390
Page
4
12

Advertisement

Table of Contents
loading

Summary of Contents for Dometic RM 3662

  • Page 1 FAX 46 141 238393 REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION. RM 3662, RM 3663 RM 3862, RM 3863 Automatic-Manual Energy Selector Contents: FOR YOUR SAFETY Page If you smell gas: Installation O p e r a t i n g lnstructions 8 1.
  • Page 2 AB ELECTROLUX FAX 46 141 238393 Cover, Reigniter FIG. 1 2 - WAY display panel. FIG. 2 3 -WAY display panel. LEGEND 3-WAY AMES Model LEGEND P-WAY AMES Model 1. Main Power Button ON/OFF 1. Main Power Button ON/OFF 2. DC Mode Selector Button 2.
  • Page 3: Electrical Connection

    141 238393 ASDF GAS CONNECTION INSTALLATION Hook-up to the gas supply fine is accomplished at the GENERAL lNSTRUCTlON manual gas valve, which is furnished with a 3/8” SAE This appliance is designed for storage of foods (UNF 5/8" -18) male flare connection. Ail completed and storage of frozen foods and making ice.
  • Page 4: Securing The Refrigerator

    '98 12/06 TIS FAX 46 141 258393 ASDFA 12 Volts DC Connection refrigerator models require a continuous 12 volt DC supply (even though 2-way models are designed to operate on 120 volts AC and gas, a 12 volt DC control is required to maintain the automatic energy system).
  • Page 5: Drain Water Hose

    46 141 238393 SDFA Hole for drain water FIG. 8 FIG. 6 Any space between the counter, storage area or ceiling and top of the refrigerator greater than 1-1/2 inches should be blocked. The heal produced at the rear of the Once the tower front strip is slipped under the hlnge, refrigerator will become trapped in thts space, making the part is possible to swing into place as shown in...
  • Page 6 For ventilation height, see table VENTILATION HEIGHTS Installation with roof Minimum ventilation See Figures 9, and 10. vent and tower side vent heights in Refrigerator Inches RM3662, RM 3663 57-3/4 1465 RM 3662; RM 3963 1620...
  • Page 7: Operating Instructions

    View from above FIG. 11 Recess Overall Refrigerator Dimensions Dimensions Model H e i g h t Width Height Width Depth Depth RM 3662 inch 54-21/32 24-7/8 26-1/32 53-3/4 23-11/16 R M a663 1366 1365 24-7/8 26-1/32 59-15/16 23-11/16 RM d 3662 ::...
  • Page 8 lwi 46 141 238393 ASDFA 2 - WAY display panel. 3 -WAY display panel. 3-WAY MODEL START UP INSTRUCTIONS AUTO MODE A continuous 12 volt DC supply must be available for the electronic control to function. Press the DC mode selector button (2) to turn OFF Press the main power ON/OFF button (1) to the the DC lamp (A).
  • Page 9: Auto Mode

    46 141 236393 3 -WAY display panel. 2 - WAY display panel. DC.MODE (3-way models only) DESCRIPTION OF OPERATING MODES When operating In the DC mode the DC mode indicator tamp (A) will be illuminated. All other mode lamps will be THERMOSTAT off.
  • Page 10: How To Use The Refrigerator

    6 cu. ft. for the models RM 3662 and panel that houses the control panel to ON. The climate RM 3663 and 6 cu. ft. for the models RM 3662, and control can be left on continuously or only used when RM 3863.
  • Page 11: Refrigerator Removal

    Refer to section INSTALLATION, page 4 to 6. Reset the lnsulation and close the lid of the boiler. 2. PERIODIC MAINTENANCE F U S E S your Dometic refrigerator operating efficient- keep ly and safely, periodic inspectlon and cleaning of The 2-way AMES models...
  • Page 12: Troubleshooting

    ASFSA 46 141 238393 B . Check all connections in the LP gas system (at the back of the refrigerator) for gas leaks. The LP gas DO NOT use a wire or pin when cleaning the burner supply must be turned on. Apply a non-corrosive jet as damage can occur to the precision opening.
  • Page 13 ASFSA...
  • Page 14 46 141 238393 ASFD KITS CERTIFIED VENT SYSTEM Model Components Drawing RM 3662 Roof Vent 3103633 Base RM3663 3103634 cap (Both Required) RM3662 RM 3663 Lower Side Vent 3102364 3102277 3102070 3102972 3101534 3101782 3101337 For further information, contact your deafer or distributor.
  • Page 15 FAX 46 141 238393 ASFD RM 3662, RM 3862 TERMINAL B L O C K BURNER HOUSING CHASSlS GROUND POINT CIRCUIT BOARD DISPLAY BOARD POWER CIRCUIT L.A.T HEATER 120 V AC HEATING CABLE PROTECT I VE EARTH 3863, RM 3863...