Operating Design

The scales in the Factory Series
consist of a weighing cell and a
display and control unit.
In addition to the choice of power
supply (via AC adapter or external
rechargeable battery pack), your
scale also has an interface port for
connecting a printer, computer
or universal remote control switch.
The display and control unit and the
weighing cell can be set up
separately. Operation of Factory
balances follows a uniform
"philosophy" which is described in
this manual.
Unless otherwise specified, the
information also refers to scale
versions verified or verifiable for use
in legal metrology (identified by the
suffix: 0CE).
Keys
The functions used most often
are assigned to their own specific
keys. There are additional
keys for assignment of other (multiple)
functions, in some cases
dependent on the current operating
status (so-called "soft keys").
Each key is described in detail in
the chapter entitled "Overview."
Normal Operation
In the operating mode, these four
keys function as c, [ISOTEST]/
[TEST], w/[TOGGLE] and v/
[FUNCTION] keys.
Standard keypad version:
ISO
TEST
U.S. and Canadian keypad version:
ON/OFF
TEST
TOGGLE FUNCTION
Setup Mode
In the setup mode, these keys
take on the function of arrow keys
(x y Y X).
I/E/
ON/OFF
Soft Key Mode
The 'soft key' functions depend on
the current operating status; the
current function is indicated in the
text line of the display. In this
example, the soft keys are used to
access Info, Menu and Input
functions.
I/E/
ON/OFF
Operating Design
Display
The display is divided into six
sections:
– Line for metrological data:
Metrological specifications of the
weighing platform.
Max ...g
Display during use as a legal
measuring instrument:
Max ...g Min ...g e=...g d=...g
– Bar graph: Display in percent of
the weight on the scale relative
to the maximum capacity and for
over/under checkweighing
– Measured value line:
Display of weight readout or
alphanumeric input
Important Note Concerning
Verified Scales Approved for Use
as Legal Measuring Instruments
in the EU*:
For verified scales that have
a verification scale interval "e"
which is greater than the scale
interval "d," the last digit on the
display is bordered.
– Weight unit display:
Weight unit, other unit of measure,
operating information
The values identified by "G" are
not allowed to be used in legal
metrological applications.
– Symbol display:
Indicates operating status;
application selected
– Text line: Prompts for operator
guidance, soft key designations
See the "Data Output" section
in the chapter entitled "Operating
the Scale" for a detailed description
of the information displayed in
each of these sections.
* including the Signatories of
the Agreement on the European
Economic Area
d=...g
3