Electrical Adjustment - Toshiba 43H72 Service Manual

N2psp chassis
Hide thumbs Also See for 43H72:
Table of Contents

Advertisement

ITEM
ƒH
1. Receive NTSC signal.
(free-running fre-
2. Short the terminal "TP +9V " and the terminal " TP (Free run) " on the signal board with a jumper
quency of Hor.
wire.
oscillator)
3. Connect the probe of frequency counter to the lead of R426 and GND.
4. Adjust the frequency to "33.75±0.2 kHz" by turning R4034 on DPC Board.
5. Disconnect the shorted wire, then confirm that the picture is synchronized.
VERTICAL POSI-
1. Receive NTSC signal.
TION (VCEN)
2. Connect he probe of digital voltmeter to TP-V and TP-G on SIGNAL Board.
3. Call up the adjustment mode display, then select the item VCEN.
4. Press the VOLUME s or t button to get the voltage 0±10 mV.
PICTURE POSITION
1. Receive NTSC signal.
(HPOS)
2. Call up the adjustment mode display.
3. Select the item "HPOS", and adjust the data to "80H".
4. Adjust the picture position alternately by turning CENTERING MAGNETS for proper picture
position.
5. Check the picture with off-air signal.
WIDTH
1. Receive NTSC signal.
(WID)
2. Call up the adjustment mode display, then select the item WID.
3. Press the VOLUME s or t button to get the picture so that left and right eddes of video signal
begin to lack.
4. Press the VOLUME s button to advance the data by 8 steps.
NOTE: Check the horizontal picture position is correct.
SUB-BRIGHTNESS
1. Constrict the picture height until the vertical retrace line
(BRTC)
appears adjusting the HEIGHT control on the MAIN board.
2. Adjust the CONTRAST to the minimum and BRIGHTNESS
to the center.
3. Enter the service mode, then select "BRTC" register.
4. Adjust the data value so the belt of vertical retrace line just
disappear.
5. Adjust the CONTRAST for the desired contrast.
6. Adjust the HEIGHT control.
SUB-COLOR
1. Receive color-bar signal from color-bar generator.
(SCOL)
2. Adjust the BRIGHTNESS and CONTRAST to the center (RESET status).
3. Connect oscilloscope to TP501on the MAIN board.
4. Enter the service mode, then select "SCOL".
5. Adjust the data value to achieve 1.8V
scope.
6. Check the picture with off-air signal.

ELECTRICAL ADJUSTMENT

ADJUSTMENT PROCEDURE
0-p
– 11 –
Vertical retrace line
Magenta
of blue bar on
0
Blue
3 (1.8V
)
0-P
2

Advertisement

Table of Contents
loading