Breakdown Self Diagnosis Function - Panasonic CS-E10JD3EA Service Manual

Air conditioner
Hide thumbs Also See for CS-E10JD3EA:
Table of Contents

Advertisement

15.3. Breakdown Self Diagnosis Function

15.3.1. Self Diagnosis Function (Three Digits Alphanumeric Code)
• Once abnormality has occurred during operation, the unit will stop its operation, and OFF/ON operation LED OFF.
• OFF indicator does not shown on remote control display.
• In operation after breakdown repair, the last error code abnormality will be stored in EEPROM.
• To make a diagnosis
1. OFF/ON operation LED OFF and the unit automatically stops the operation, but the OFF indicator does not shown.
2. Press CHECK button continuously for 5 seconds.
3. "- -" will be displayed on the remote controller display.
4. Press timer
or
5. Every press of the button (
6. When the displayed error code matches the unit's error code, OFF/ON operation LED will be ON
continuously.
7. The breakdown diagnosis mode will be cancelled by pressing CHECK button continuously for 5 seconds or wait for 30
seconds.
• AC Reset button
When AC Reset button is pressed, the error code will be
reset so that the unit will be able to operate and recheck if
any error occurred.
• To display memorized error status:
1. Turn ON the power supply.
2. Press CHECK button continuously for 5 seconds.
3. "- -" will be displayed on the remote controller display.
4. Press timer
or
5. Every press of the button (
6. When the displayed error code matches the unit's error code, OFF/ON operation LED will be ON
continuously.
7. The breakdown diagnosis mode will be cancelled by pressing CHECK button continuously for 5 seconds or wait for 30
seconds.
button on the remote control. The error code "H00" (no abnormality) will be displayed.
or
) will increase the error code number.
button on the remote control. The error code "H00" (no abnormality) will be displayed.
or
) will increase the error code number.
58

Hide quick links:

Advertisement

Table of Contents
loading