Checking The Sensor Output - Canon DADF-Q1 Service Manual

Feeder
Table of Contents

Advertisement

Chapter 4
Switch
SW3
SW4
*0.1% (image reproduction ratio).
3) Press the push switch SW3 or SW4 on the ADF controller PCB to adjust
the speed of reversal by referring to theable.
J16
J15
J1
J2
J4
CB1
SW1
J5
DSP1
SW4SW3SW2
J3
J6
DIS1
4-26
[2]
[1]
F-4-122
F-4-123
DSP1
Adjust
indicat
ment
Switc
ion
value*
h
A-E2
-30
SW3
A-E3
-29
A-E4
-28
A-E5
-27
A-E6
-26
A-E7
-25
A-E8
-24
A-E9
-23
A-EA
-22
A-Eb
-21
A-Ec
-20
A-Ed
-19
A-Ee
-18
A-Ef
-17
A-F0
-16
A-F1
-15
A-F2
-14
A-F3
-13
A-F4
-12
A-F5
-11
A-F6
-10
SW4
J14
J13
J12
IC8
J7
J8
J9
J10
J11
F-4-125
Sensor in question (notation)
Original sensor (S6)
(1)
2) Pres the push switch (SW2).
- DSP 1 displays the current volume by flushing.
DSP1
indicati
on
Adjustment value*
A-F7
-9
A-F8
-8
A-F9
-7
A-FA
-6
A-Fb
-5
A-FC
-4
A-Fd
-3
A-FE
-2
A-FF
-1
A-00
0 (reference value)
A-01
1
A-02
2
A-03
3
A-04
4
A-05
5
A-06
6
A-07
7
A-08
8
A-09
9
A-0A
10
A-0b
11
SW3
SW4
4) At the end of the operation, press the push switch (SW2) on the ADF con-
troller.

4.3.3.5 Checking the Sensor Output

The DADF uses a 7-segment LED (DSP1) on its ADF controller PCB to al-
low a check on the presence/absence of paper or the state (open/closed) of
the upper cover of the following sensors:
Sensor in question (notation)
DSP1
Reversal sensor (S1)
(7)
J16
J15
J1
J2
J4
CB1
SW1
J5
IC8
DSP1
SW4SW3SW2
J3
J6
J7
J8
J9
J10
F-4-124
T-4-19
DSP1
Adjust
Switc
indicati
ment
h
on
value*
SW3
A-0C
12
A-CD
13
A-CE
14
A-CF
15
A-10
16
A-11
17
A-12
17
A-13
18
A-14
19
A-15
20
A-16
21
A-17
22
A-18
23
A-19
24
A-1A
25
A-1b
26
A-1C
27
A-1d
28
A-1E
29
A-1F
30
SW4
-
-
T-4-20
Switch
Change
Increase the speed of reversal.
Decrease the speed of reversal.
T-4-21
J14
J13
J12
J11
0011-3522