Continuous Polling

Use this procedure to poll the
1
same remote facsimile(s) on a
regular schedule. Continuous
Polling operations can be pro-
grammed for specific time inter-
Press:
vals on the days selected. In ad-
dition, a 4-digit security code
can be used with other TOSHI-
BA facsimiles when the docu-
ment has a security code pro-
grammed.
NOTES:
Calls are performed with-
in the set time period on
the days selected with
the set interval between
callings.
If multiple sending sta-
tions are programmed,
callings are performed to
all those stations within
the set time period.
If the polling operation
exceeds the set time pe-
riod, it will continue until
all the facsimiles have
been polled.
Redialing or calling to al-
ternate dialing numbers is
not available during this
operation.
If a power failure occurs
during this procedure, the
polling continues when
power is restored.
If the set time period is
shorter than the set call-
ing interval, polling will be
performed only once at
the start time.
130
2
Display the
POLLING Menu
Select "04.PROG. CONT.
POLL." by pressing:
+
+
POLLING
01.POLLING
02.POLLING RESERVE
03.TURNAROUND POLL
04.PROG. CONT. POLL.
3
Select PROG. CONT.
POLL.
Enter the time interval between
polling sequences (10 to 70
minutes).
Only interval settings of 10-
minute increments are permis-
+
sible. (Example: Enter "1" for
10 minutes or "2" for 20 min-
utes, etc.)
INTERVAL
(10-70)
[
0]
Then press:
START/STOP TIME
[08:00AM-05:00PM]
4
Enter the Polling
Enter the Start and
Interval
Stop Time
Enter the polling start and stop
time.
When the time period is dis-
played correctly, press:
NOTES:
• You may use
move the cursor left and
right.
• If the 12-hour format is se-
lected, you may use the
lect AM or PM.
START/STOP DAYS
[MON-FRI]
/
to
/
keys to se-
↑↓