● Setting
- Set binning operation
Set the following value to "BinningHorizontal", "BinningVertical" registers. Setting value is Integer type.
"BinningHorizontal" is the number of horizontal pixel(s) to add. And "BinningVertical" is the number of
vertical pixel(s) to add.
Minimum (*)
Maximum
● Note
The range of register setting depends on camera model.
Changing "BinningHorizontal", "BinningVertical" register value effects Scalable registers.
Changing "BinningHorizontal", "BinningVertical" register value is invalid during image stream data output.
Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved.
Model
BG030
1(H)×1(V)
2(H)×2(V)
BG031
BG080
1(H)×1(V)
1(H)×1(V)
2(H)×2(V)
2(H)×2(V)
* initial factory setting
36 / 69
BG130
1(H)×1(V)
2(H)×2(V)